Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DERICK AMES ROOFING AND PAINTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DERICK AMES ROOFING AND PAINTING in 3884 EAST STREET, PITTSBURGH, PA 15212 (NAICS 423330). OSHA activity number 339130213.

Watch Derick Ames Roofing AND Painting — free Get an email when a new federal OSHA severe-injury report for Derick Ames Roofing AND Painting is published. One employer, no account, unsubscribe in one click.
Site address
3884 EAST STREET
City
PITTSBURGH
State
PA
ZIP
15212
Mailing
5532 RIPPEY PLACE, PITTSBURGH, PA 15206
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure:    a) Job site, 3884 East Street, Pittsburgh, PA: On or about June 8, 2013, during roofing activities, the employer did not ensure that employees used fall protection systems/devices where exposed to fall hazards of up to approximately 35 feet.
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access or when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:   a) Job site, 3884 East Street, Pittsburgh, PA: On or about June 8, 2013, during roofing activities, the employer did not ensure that the ladders set up at the job site to access/egress the roof area were extended at least 3 feet above the landing surface. Ladders were extended approximately 6-12" above the landing surfaces, exposing an employee to fall hazards of up to approximately 30-35 feet.
Recent events (1)
  • — Z (S) $2000