BROOKLYN, NY —
OSHA Inspection: PHILLIP HOWARD APARTMENTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PHILLIP HOWARD APARTMENTS in 1655 FLATBUSH AVENUE, BROOKLYN, NY 11210 (NAICS 531311). OSHA activity number 339149619.
Where did this inspection happen?
- Establishment
- PHILLIP HOWARD APARTMENTS
- Site address
- 1655 FLATBUSH AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11210
- Mailing
- 1655 FLATBUSH AVENUE, BROOKLYN, NY 11210
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 531311
- Employees
- 17
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.37 B04
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $2400.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: Location: 1655 Flatbush Avenue, Brooklyn, NY. Basement Leading to Parking Garage. Exit sign was not posted indicating the direction of travel to the nearest exit from the floor. On or about 6/26/2013.
Recent events (3)
- — F (S) $2400
- — C (S) $4000
- — Z (S) $4000
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Location: 1655 Flatbush Avenue, Brooklyn, NY. Fire extinguishers had not been inspected within the last 12 months. On or about 6/26/2013.
Recent events (3)
- — F (S) $1800
- — C (S) $3000
- — Z (S) $3000
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by unprotected compactor safety switch. Location: 1655 Flatbush Avenue, Brooklyn, NY. Compactor C. Employees ussed a compactor which did not have a operational guard when using hte compactor. On or about 06/26/2013
Recent events (3)
- — F (S) $4200
- — C (S) $7000
- — Z (S) $7000
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $2400.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. Location: 1655 Flatbush Avenue, Brooklyn, NY. Compactor A. a) Electrical junction boxes were not provided with covers to protect the live electrical wires installed within. On or about 06/26/2013 Location: 1655 Flatbush Avenue, Brooklyn, NY. Compactor B. b) Electrical junction boxes were not provided with covers to protect the live electrical wires installed within. On or about 06/26/2013. Location: 1655 Flatbush Avenue, Brooklyn, NY. Compactor C. Electrical junction boxes were not provided with covers to protect the live electrical wires installed within. On or about 06/26/2013.
Recent events (3)
- — F (S) $2400
- — C (S) $4000
- — Z (S) $4000
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted in paragraph (g) (1) (ii) of this section, flexible cords and cables cannot be used as a substitute for fixed wiring. Location: 1655 Flatbush Avenue, Brooklyn, NY. Compactor B. Floor fan, and other electrical equipment were provided power by a temporary power strip/extension cord, in lieu of fixed wiring. On or about 06/26/2013.
Recent events (3)
- — F (S) $0
- — C (S) $4000
- — Z (S) $4000
1904.29 A
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1904.29(a): A log of all Work-Related Injuries and Illnesses (OSHA Form 300) and /or the Summary of Work-Related Injuries and Illnesses (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment: Location: Establishment. a) The employer did not keep a log of all Work-Related Injuries and Illnesses for calendar year 2013. On or about 6/26/2013. Location: Establishment. b) The employer did not keep the Injury and Illnesses Incident Report (OSHA Form 301 or equivalent form for calendar year 2013. On or about 6/26/2013.
Recent events (3)
- — F (O) $700
- — C (O) $1000
- — Z (O) $1000
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Location: 1655 Flatbush Avenue, Brooklyn, NY. The employer did not develop a written hazard communication program for chemical used in the work place such as but not limited to liquid crystallization, really general purpose foaming disinfectant cleaner, green heavy cleaner, motor oil. On or about 06/26/2013.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in the work place. Location: 1655 Flatbush Avenue, Brooklyn, NY. The employer did not maintain material safety data sheets for chemicals such as but not limited to: liquid crystallization, really general purpose foaming disinfectant cleaner, green heavy cleaner, motor oil. On or about 06/26/2013.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees did not provided information and training to employees on the hazardous chemicals in their work place. Location: 1655 Flatbush Avenue, Brooklyn, NY. Employees were not trained in the hazards associated with chemicals such as but not limited to: liquid crystallization, really general purpose foaming disinfectant cleaner, green heavy cleaner, motor oil. On or about 06/26/2013.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 531311)
BRONX, NY—2026-07-08
WOODSTOCK TERRACE MUTUAL HOUSING
PINELLAS PARK, FL—2026-07-07
GREYSTAR MANAGEMENT SERVICES LLC
BURBANK, CA—2026-07-02
EQUITY RESIDENTIAL
VANCOUVER, WA—2026-06-18
WA317991735 - DELTA MANAGEMENT CO LLC
PUNTA GORDA, FL—2026-06-17
HERITAGE STATION BY MARONDA HOMES
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339149619.