SAINT LOUIS, MO —
OSHA Inspection: THE PRINTING SOURCE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE PRINTING SOURCE, INC. in 2373 BALL DRIVE, SAINT LOUIS, MO 63146 (NAICS 323110). OSHA activity number 339169310.
Where did this inspection happen?
- Establishment
- THE PRINTING SOURCE, INC.
- Site address
- 2373 BALL DRIVE
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63146
- Mailing
- 2373 BALL DRIVE, SAINT LOUIS, MO 63146
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 39
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.106 E06 II
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $893.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container electrically interconnected, bonded and grounded: (Where the metallic floor plate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.) In the chemical storage room, the 55-gallon drum of isopropyl alcohol stored in the flammable storage cabinet and dispensed approximately twice per week, was not grounded and bonded.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $893.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: a) In the Press room, the operator used an air nozzle for cleaning purposes that measured approximately 65 p.s.i. b) In the Bindery department, PMC die cutting machine, the operator used an air nozzle for cleaning purposes that measured approximately 80 p.s.i.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $1517.00 · Current $759.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: In the Bindery department the cord servicing the Challenge drill press used approximately 2-3 times per week was pulled away from the plug approximately 1 1/2 inches, resulting in lack of strain relief.
Recent events (2)
- — I (S) $758.5
- — Z (S) $1517
More inspections at THE PRINTING SOURCE, INC.
ST. LOUIS, MO—2009-12-01 00:00:00
THE PRINTING SOURCE, INC.
View THE PRINTING SOURCE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323110)
MINNEAPOLIS, MN—2026-05-20
111284 - MARTH GROUP LLC DBA ENPOINTE
GLENDALE, KY—2026-02-04
68801 - PG-GERALD LLC
PORTLAND, OR—2026-01-16
317742947 - PEP PRINTING INC
MINNEAPOLIS, MN—2025-11-18
110299 - OMEGA LITHOGRAPH INC
BELLINGHAM, WA—2025-09-05
WA317987718 - CAPITOL CITY PRESS INC
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source