OSHKOSH, WI —
OSHA Inspection: EXTREME EXTERIORS, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EXTREME EXTERIORS, INC in NORTH SCOTT RESIDENCE HALL, OSHKOSH, WI 54903 (NAICS 238150). OSHA activity number 339172785.
Where did this inspection happen?
- Establishment
- EXTREME EXTERIORS, INC
- Site address
- NORTH SCOTT RESIDENCE HALL
- City
- OSHKOSH
- State
- WI
- ZIP
- 54903
- Mailing
- S83 W23025 ARTESIAN AVE, BIG BEND, WI 53103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 9
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 A06
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person: a) On 7/10/13, the suspended scaffold was not assembled or rigged in accordance with a design by a qualified person in that tie backs, anchors, and fall protection systems were not properly evaluated or installed.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 D03 IX
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(d)(3)(ix): Tiebacks were not secured to a structurally sound anchorage on the building or structure: a) On 7/10/13, the tiebacks for the suspended scaffold on the north side of the building were connected to a park bench on the east end and a fall protection anchor embedded into the sidewalk on the west end.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 D12 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(d)(12)(ii): Wire rope clips used on suspension scaffold ropes were not installed according to the manufacturer's recommendations: a) On and before 7/10/13, the Fist Grip wire rope clips were not installed according to Crosby's instructions relative to spacing or torque value.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; such activities were not performed only by experienced and trained employees selected for such work by the competent person: a) On and before 7/10/13, the employees and competent person were not able to evaluate or identify suitable structures to tie back the suspended scaffold or to properly install the tie backs to suitable anchorages.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On 7/10/13, an employee was working on the roof of the building carrying scrap material to the opposite side of the building without fall protection.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.502 D15
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) On 7/10/13, employees working from a suspended scaffold had their personal fall arrest systems connected to structures that were unlikely to support 5000 lbs. and tied in a means that would compromise the strength of the lifelines.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On 7/10/13, an extension ladder was used to access the roof surface when the side rails did not extend more than 2 feet above the roof surface.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections at EXTREME EXTERIORS, INC
PENSACOLA, FL—2023-08-15 00:00:00
EXTREME EXTERIORS INC.
MADISON, WI—2014-04-08 00:00:00
EXTREME EXTERIORS, INC
View EXTREME EXTERIORS, INC's full OSHA safety record →
More inspections in this industry (NAICS 238150)
HARRISBURG, PA—2026-07-02
HERSHOCKS INC
HARRISBURG, PA—2026-07-02
HERSHOCKS INC
HOLLISTER, CA—2026-06-29
PAC CON GLAZING. INC.
SAN ANTONIO, TX—2026-06-24
ARROWALL COMPANY
BALTIMORE, MD—2026-06-15
A-L ABATEMENT, INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source