LAFAYETTE, LA —
OSHA Inspection: WILCO MANUFACTURING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WILCO MANUFACTURING, LLC in 183 S. BEADLE RD, LAFAYETTE, LA 70508 (NAICS 333120). OSHA activity number 339175309.
Where did this inspection happen?
- Establishment
- WILCO MANUFACTURING, LLC
- Site address
- 183 S. BEADLE RD
- City
- LAFAYETTE
- State
- LA
- ZIP
- 70508
- Mailing
- 183 S. BEADLE RD BLDG B, LAFAYETTE, LA 70508
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333120
- Employees
- 35
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour. On or about July 11, 2013, in the Fabrication shop, the employer allowed employees to store oxygen and acetylene gas cylinders together on a cart with the regulator gage on them.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.253 E01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer: On or about July 11, 2013, at Wilco Fabrication, the employer allowed employees to use pressure gages on gas cylinders that were missing the protective covering. 1) In the Pre-Fab area the pressure gage for the gas cylinder was missing the protective covering 2) In the Fabrication area the pressure gage for the acetylene gas cylinder was missing two protective coverings.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 A02 I B
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(i)(B): Temporary wiring was used for a period exceeding 90 days. On or about July 11, 2013, in the Parts Storage area, the employer allowed employees to utilize an extension cord as permanent wiring. The extension cord was used as a power source for a Maxess fan.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 A02 X
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. On or about July 11, 2013, in the Parts Stroage Room an extension cord was passed through the perimeter wall to the exterior smoking area. The extension cord was attached to a Maxess fan.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01
- Issued
- Penalty
- Initial $1785.00 · Current $1071.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed: On or about July 11, 2013, at Wilco Manufacturing, LLC in the Pre-Fab area the employer allow employees to utilize a 120V handy box receptical as a power source for a fan. The handy box was not effectively closed.
Recent events (2)
- — I (S) $1071
- — Z (S) $1785
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about July 11, 2013, the following fire extinguishers were not identified or readily accessible employees were welding in the Pre-Fab area and near the Track Shop and Parts Storage Room. 1) In the Pre-Fab area, Fire extinguisher # 858505 was not identified with a label 2) In the Track Shop Area, Fire extinguisher #553251 was blocked by equipment 3) In the Track Shop Area, Fire extinguisher #858513 was blocked by equipment 4) In the Parts Storage Room, (2) two Fire extinguishers were not identified with a label
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate material safety data sheet: On or about July 11, 2013, at Wilco Manufacturing, LLC, the employer did not provide a list of the hazardous chemicals known to be present in the work place in the written hazard communication program.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333120)
MENOMINEE, MI—2026-07-09
JP SKIDMORE LLC
SAINT PAUL, MN—2026-07-08
111549 - SCHWING AMERICA, INC.
CARROLLTON, KY—2026-07-07
69280 - KEMPER CONSTRUCTION LLC
LONG PRAIRIE, MN—2026-06-16
111422 - JENKINS IRON AND STEEL INC
SHAWANO, WI—2026-06-11
TIMBERPRO, INC.
More inspections in LA
LAFAYETTE, LA—2026-07-15
GULLEY'S WELDING & STEEL ERECTORS, INC.
LAFAYETTE, LA—2026-07-15
ACORREA COMPANY, LLC
LAFAYETTE, LA—2026-07-14
GULF COAST WOODWORK, L.L.C.
BELLE ROSE, LA—2026-07-14
OXYCHEM
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339175309.