Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CAROLINA ACCENTS OF MISSISSIPPI INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAROLINA ACCENTS OF MISSISSIPPI INC. in 190 CR 562, RIPLEY, MS 38663 (NAICS 337121). OSHA activity number 339215816.

Watch Carolina Accents OF Mississippi INC. — free Get an email when a new federal OSHA severe-injury report for Carolina Accents OF Mississippi INC. is published. One employer, no account, unsubscribe in one click.
Site address
190 CR 562
City
RIPLEY
State
MS
ZIP
38663
Mailing
190 CR 562, RIPLEY, MS 38663
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337121
Employees
8
Ownership type
A

7 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1020.00 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,     (a) Facility - On or about July 17, 2013 employees work on a metal roof to repair leaks without guardrail system or personal fall arrest system. Employees were exposed to falling up to 30 feet to a lower level.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2000

1910.147 C01

Serious Gravity 5 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1020.00 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.     (a) Facility - On or about July 17, 2013 the employer did not have a written energy control program that had the equipment listed, specific lock out procedures to deenergize the equipment, person/s responsible for conducting periodic inspections and certification of training of affected and authorized employees that is related to their specific machinery.  Mattison rip saw, De Walt radial arm saws and a vertical band saw were some of the equipment serviced by employees at the jobsite.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2000

1910.157 D02

Serious Gravity 1 3 instances 3 exposed
Issued
Penalty
Initial $1020.00 · Current $558.00 Reduced
29 CFR 1910.157(d)(2): The employer shall distribute portable fire extinguishers for use by employees on Class A fires so that the travel distance for employees to any extinguisher is 75 feet (22.9 m) or less.     (a) Production Area - On or about July 17, 2013 there were no fire extinguishers for the employees to use in this area which measured approximately 60 feet x 160 feet.
Recent events (2)
  • — I (S) $558
  • — Z (S) $1020

1910.178 L06

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $612.00 Reduced
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.    (a) Facility - On or about July 17, 2013 forklift operators have not been certiified by the employer.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1200

1910.212 A03 II

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $612.00 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.       (a) Facility - On or about July 17, 2013 employee operates two Juki single stitch sewing machines without needle guards.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1200

1910.213 H01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1020.00 Reduced
29 CFR 1910.213(h)(1): The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.     (a) Frame Department - Employees operate two 16 inch De Walt radial arm saws that did not have the lower blade guarded.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2000

1910.303 F02

Serious Gravity 1 2 instances 3 exposed
Issued
Penalty
Initial $1200.00 · Current $558.00 Reduced
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.    (a) Upholstery Department - On or about July 17, 2013 two breaker panels did not have the circuit breakers identified.
Recent events (2)
  • — I (S) $558
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339215816.