YULEE, FL —
OSHA Inspection: DOOR FABRICATION SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DOOR FABRICATION SERVICES, INC. in 86550 GENE LASSERRE BLVD, YULEE, FL 32097 (NAICS 238350). OSHA activity number 339227084.
Where did this inspection happen?
- Establishment
- DOOR FABRICATION SERVICES, INC.
- Site address
- 86550 GENE LASSERRE BLVD
- City
- YULEE
- State
- FL
- ZIP
- 32097
- Mailing
- 86550 GENE LASSERRE BLVD., YULEE, FL 32097
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 65
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Penalty
- Initial $2529.00 · Current $1517.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about July 17, 2013, in the production department, the Mitre-mite bottom stapler did not have a guard, exposing employees to a caught-by hazard. b. On or about July 17, 2013, in the maintenance shop, the Grizzly Drilll Press did not have a guard on the chuck, exposing employees to flying debris and drill bits.
Recent events (2)
- — I (S) $1517.4
- — Z (S) $2529
1910.304 G05
- Issued
- Penalty
- Initial $2380.00 · Current $1428.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On or about July 17, 2013, in the production department, three pedestal fans did not have continuous grounding because the ground pin was missing or not in place, exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.157 E02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a. On or about July 17, 2013, throughout the facility, approximately 20 portable fire extinguishers were not visually inspected in order to ensure that they were in good working condition.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a. On or about July 17, 2013, in the maintenance shop, the electrical breaker panel was blocked by equipment and material, thereby preventing employees to access the panel in case of an emergency.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DOOR FABRICATION SERVICES, INC.
VANDALIA, OH—2003-11-20 00:00:00
DOOR FABRICATION SERVICES INC
WOODBURY HEIGHTS, NJ—2001-04-23 00:00:00
DOOR FABRICATION SERVICES, INC.
PHOENIX, AZ—2000-01-25 00:00:00
DOOR FABRICATION SERVICES, INC.
View DOOR FABRICATION SERVICES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339227084.