EL PASO, TX —
OSHA Inspection: PIPO ACADEMY
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PIPO ACADEMY in 3000 PERSHING, EL PASO, TX 79905 (NAICS 812112). OSHA activity number 339235277.
Where did this inspection happen?
- Establishment
- PIPO ACADEMY
- Site address
- 3000 PERSHING
- City
- EL PASO
- State
- TX
- ZIP
- 79905
- Mailing
- 3000 PERSHING, EL PASO, TX 79905
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812112
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.62 D01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level. On July 19, 2013, and times prior to, employer did not initially determine employees working inside a building under demolition were exposed to lead. This condition exposed employee to potential health hazards associated with lead.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.403 B01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. An indoor electrical juntction was used as part of an extension cord to power the welder. This conditon exposed employee to potential electrical hards.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. On July 19, 2013, and times prior to employees were using a welder that was not free from recognized hazards. An open electrical box place on the outside of the welder was not fully enclosed. This condition exposed employee to potential electrical hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections in this industry (NAICS 812112)
PORTLAND, OR—2026-06-29
317744188 - BALM PDX LLC
TROY, NC—2026-06-15
161364 - MERLE HARRIS
SANTA CLARITA, CA—2026-06-09
JOHN PAUL MITCHELL SYSTEMS INC
WESTON, FL—2026-05-13
GENIA'S KERATIN SPA LLC
CENTRAL FALLS, RI—2026-03-31
TSG INVESTMENTS LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339235277.