Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIMENSION GRAPHICS, INC. AND ITS SUCCESSORS INCLUDING PRINT SOLUTIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIMENSION GRAPHICS, INC. AND ITS SUCCESSORS INCLUDING PRINT SOLUTIONS, INC. in 13915 W. 107TH ST., LENEXA, KS 66215 (NAICS 323110). OSHA activity number 339241705.

Watch Dimension Graphics, INC. AND ITS Successors Including Print Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Dimension Graphics, INC. AND ITS Successors Including Print Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13915 W. 107TH ST.
City
LENEXA
State
KS
ZIP
66215
Mailing
13915 W. 107TH ST., LENEXA, KS 66215
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.219 D01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1496.00 · Current $250.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    In the folder area, M1000 print press has unguarded pulley for feed rate sensor, exposing employees to a caught in hazard.
Recent events (3)
  • — F (O) $250
  • — C (S) $1496
  • — Z (S) $1496

1910.219 E02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(2)(i): Overhead horizontal belt(s) with lower parts seven -7 feet or less from the floor(s) or platform(s) were not guarded on the sides and bottom in accordance with the requirements specified at CFR 1910.219(o)(3)(a):    In the folder area, M1000 print press has unguarded belt for the feed rate sensor, exposing employees to a caught in hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 F02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1122.00 · Current $500.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    Near the M1000 Printing Press, Circuit Breaker #4 had six circuit breakers unlabelled to indicate their purpose, exposing employees to potential fire hazard.
Recent events (3)
  • — F (O) $500
  • — C (S) $1122
  • — Z (S) $1122

1910.304 B03 II C 3

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1122.00 · Current $0.00 Reduced
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug were not visually inspected before use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage, and equipment found damaged or defective was not removed from use until repaired:    In the shop, the Plate Bender plug and cord assembly was not inspected or removed from service due to observed safety hazards in that the electrical cord's insulation was damaged, exposing employees to an electrical shock hazard.
Recent events (3)
  • — F (O) $0
  • — C (S) $1122
  • — Z (S) $1122

1910.305 B01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1122.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    In the shop, unused openings in electrical equipment were uncovered, exposing employees to electrical shock in the following two instances:    1) Circuit breaker panel 4(a), had openings created by improperly sized blanks installed over two vacant circuit breaker slots.    2) Plate bender on/off switch box was missing two knockouts.
Recent events (3)
  • — F (O) $0
  • — C (S) $1122
  • — Z (S) $1122

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339241705.