SEBRING, FL —
OSHA Inspection: GRIFFIN DRY CLEANING AND LAUNDRY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GRIFFIN DRY CLEANING AND LAUNDRY, INC. in 212 RIDGEWOOD DR., SEBRING, FL 33870 (NAICS 333312). OSHA activity number 339244881.
Where did this inspection happen?
- Establishment
- GRIFFIN DRY CLEANING AND LAUNDRY, INC.
- Site address
- 212 RIDGEWOOD DR.
- City
- SEBRING
- State
- FL
- ZIP
- 33870
- Mailing
- 212 RIDGEWOOD DR., SEBRING, FL 33870
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333312
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) For the dry cleaning facility at 212 Ridgewood Dr., Sebring, FL 33870, as observed on or about 07/31/2013, no exit sign was present for any of the exits in the building.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.37 B05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or identified by a sign indicating its actual use (e.g. closet): a) For the dry cleaning facility at 212 Ridgewood Dr., Sebring, FL 33870, as observed on or about 07/31/2013, rear doors that were kept locked at all times were not marked "Not an Exit".
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.38 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.38(a): 29 CFR 1910.38(a)(1): The emergency action plan required by 29 CFR 1910.157(a) or (b) when the employer has elected to partially or totally evacuate the workplace in the event of a fire emergency, or required by 29 CFR 1910.160(c)(1), did not cover the designated actions that the employer or employees must take to ensure employee safety from the fire and other emergencies: a) For the dry cleaning facility at 212 Ridgewood Dr., Sebring, FL 33870, as observed on or about 07/31/2013, employees were not familiar with evacuation procedures or whether total evacuation was always required in event of an emergency/fire, or only sometimes required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C02 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(2)(ii): The employer's tagout energy control program procedures did not successfully comply with 29 CFR 1910.147(c)(3) and no lockout was provided for employee protection: For the dry cleaning facility at 212 Ridgewood Dr., Sebring, FL 33870, as observed on or about 07/31/2013 and 08/06/2013: a) No locks were used in the isolation of steam line valves and air line valves during maintenance activities. Tags used were not securely fastened to equipment/piping, but instead hung loosely and could easily fall off when touched. Tags used also did not indicate the nature of the hazardous energy present and contained no warning legend relating to the hazardous energy.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) For the dry cleaning facility at 212 Ridgewood Dr., Sebring, FL 33870, as observed on or about 07/31/2013 and 08/06/2013: maintenance was performed on steam presses at the facility. Hazardous energy existed in the form of high temperature pressurized steam and compressed air. Multiple valves were present controlling steam flow and compressed air. No specific procedures were in place for hazardous energy isolation and lockout tagout of equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a) For the dry cleaning establishment at 212 Ridgewood Drive, Sebring, FL 33870, as observed on or about 07/31/2013, the dry cleaning building was filled with clutter, garbage, boxes, and containers that made it difficult to access work areas and resulted in an unsanitary environment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the dry cleaning establishment at 212 Ridgewood Drive, Sebring, FL 33870, as observed on or about 07/31/2013, a flexible power strip was used to supply electricity to a Rinnai water heater on the production/dry cleaning floor. Use of a flexible power strip with industrial equipment is not within its intended, designed use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333312)
WESTWOOD, KY—2021-07-15 00:00:00
63967 - GREEN EARTH CLEANERS LLC
ROUND ROCK, TX—2020-09-14 00:00:00
PRUDENTIAL OVERALL SUPPLY
COLVILLE, WA—2020-07-24 00:00:00
WA317960310 - COLMAC INDUSTRIES INC
GUAYNABO, PR—2020-02-28 00:00:00
LUAR CLEANERS
NEW BEDFORD, MA—2020-02-25 00:00:00
CLEAN RENTALS INCORPORATED
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source