ROCKVILLE CENTRE, NY —
OSHA Inspection: JOHN G. HUBLER & SONS ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOHN G. HUBLER & SONS ROOFING in 21 VANDERBUILT STREET, ROCKVILLE CENTRE, NY 11570 (NAICS 238160). OSHA activity number 339251415.
Where did this inspection happen?
- Establishment
- JOHN G. HUBLER & SONS ROOFING
- Site address
- 21 VANDERBUILT STREET
- City
- ROCKVILLE CENTRE
- State
- NY
- ZIP
- 11570
- Mailing
- 125 N. PARK AVENUE, ROCKVILLE CENTRE, NY 11570
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 14
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) Worksite, Northside - Employees installing shingles on a roof with a nailgun, were not provided with eye protection; on or about 08/06/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.501 B13
- Issued
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, Northside - Employees installing shingles on an approximate 8-12 pitch roof, approximately 10 feet above the ground, did not have fall protection; on or about 08/06/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) Worksite, Southside - Employees installing shingles were using a closed stepladder to ascend the roof, approximately 10 feet above the ground; on or about08/06/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339251415.