Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LOWES HOME CENTER INC. #2928

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOWES HOME CENTER INC. #2928 in 12100 MONTANA AVE., EL PASO, TX 79938 (NAICS 444110). OSHA activity number 339253247.

Watch Lowes Home Center INC. #2928 — free Get an email when a new federal OSHA severe-injury report for Lowes Home Center INC. #2928 is published. One employer, no account, unsubscribe in one click.
Site address
12100 MONTANA AVE.
City
EL PASO
State
TX
ZIP
79938
Mailing
1000 LOWES BLVD., MOORESVILLE, NC 28117
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
262000
Ownership type
A

2 citations on file for this inspection.

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4675.00 · Current $2400.00 Reduced
29 CFR 1910.305(b) (1) (ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:      On or about August 5, 2013, in the front electrical room, the employer did not place filler plates in the breaker box, exposing energized parts. This condition exposed the employees to electrical hazards.
Recent events (2)
  • — I (O) $2400
  • — Z (S) $4675

1910.101 B

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tank was not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   On or about August 8, 2013, a compressed gas cylinder of helium was not secured when stored in the receiving area at Lowes. This condition exposed the employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339253247.