SYRACUSE, NY —
OSHA Inspection: O'NEILL'S CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of O'NEILL'S CONSTRUCTION in 1418-1420 EAST GENESEE STREET, SYRACUSE, NY 13210 (NAICS 238160). OSHA activity number 339255457.
Where did this inspection happen?
- Establishment
- O'NEILL'S CONSTRUCTION
- Site address
- 1418-1420 EAST GENESEE STREET
- City
- SYRACUSE
- State
- NY
- ZIP
- 13210
- Mailing
- 891 STATE ROUTE 31, BRIDGEPORT, NY 13030
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 1418-1420 East Genesee Street, Syracuse NY - On or about 6 August, 2013 - Employees were working on a residential roof above 6 feet without the use of personal fall protection.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 1418-1420 East Genesee Street, Syracuse NY - On or about 6 August, 2013 - Employees were using an extension ladder to gain access to the residential roof that did not have the side rails extended a minimum of 3 feet above the upper landing surface.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B22
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause them to lose balance and fall: a) 1418-1420 East Genesee Street, Syracuse NY - On or about 6 August, 2013 - Employees were climbing and carrying plywood sheathing material up an extension ladder to the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B21
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(21): Each employee was not grasping the ladder with at least one hand when progressing up and/or down the ladder: a) 1418-1420 East Genesee Street, Syracuse NY - On or about 6 August, 2013 - Employees were climbing and carrying materials up an extension ladder to the roof and did not grasp the ladder with at least one hand.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) 1418-1420 East Genesee Street, Syracuse NY - On or about 6 August, 2013 - Employees were working without the use of head protection while materials and employees were over 20 feet above their heads on the roof.
Recent events (2)
- — I (O) $0
- — Z (S) $2400
1926.404 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 1418-1420 East Genesee Street, Syracuse NY - On or about 6 August, 2013 - Employees were using electrical power tools supplied power through extension cords directly plugged into the residence that were not ground fault circuit interrupter protected.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339255457.