Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BLACKWOOD GROUP LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BLACKWOOD GROUP LLC in 3153 S. GILES AVENUE, CHICAGO, IL 60616 (NAICS 238130). OSHA activity number 339265845.

Watch Blackwood Group LLC — free Get an email when a new federal OSHA severe-injury report for Blackwood Group LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BLACKWOOD GROUP LLC
Site address
3153 S. GILES AVENUE
City
CHICAGO
State
IL
ZIP
60616
Mailing
2701 W. FULTON STREET 1N, CHICAGO, IL 60612
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.403 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.403(b)(1): Examination. The employer shall ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined on the basis of the following considerations:  a) On or about August 7, 2013 - at the jobsite located at 3153 S. Giles Avenue, Chicago, IL. - the employer did not ensure that the temporary electric system on the jobsite was free from recognized hazards, in that the electrical box was not kept clean and free of debris and accumulative dust, thereby exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.405 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(2): Covers and canopies.  All pull boxes, junction boxes and fittings shall be provided with covers:  a) On or about August 7, 2013 - at the jobsite located at 3153 S. Giles Avenue, Chicago, IL. - the electric panel box in the basement of the building was not equipped with a cover, thereby exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.403(d)(1): Mounting. Electric equipment shall be firmly secured to the surface on which it is mounted. Wooden plugs driven into holes in masonry, concrete, plaster, or similar materials shall not be used.  a) On or about August 7, 2013 - at the jobsite located at 3153 S. Giles Avenue, Chicago, IL. - the employer did not ensure that a temporary electric outlet used to power hand-held tools; including but not limited to drills, nail guns and band saws was not secured or mounted, thereby exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.404 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.  a) On or about August 7, 2013 - at the jobsite located at 3153 S. Giles Avenue, Chicago, IL. - the electrical outlets used to power hand-held tools; including but not limited to drills, nail guns and band saws were not protected by ground-fault circuit interrupters or an assured equipment grounding conductor program, thereby exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76cm) whichever is less, shall be equipped with at least one handrail;   a) On or about August 7, 2013 - at the jobsite located at 3153 S. Giles Avenue, Chicago, IL. - Employees performing carpentry activities in a rehab were using a staircase that was not equipped with handrails, thereby exposing the employees to fall hazards of approximately eight (8) and half (1/2) feet.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1052 C12

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.  a) On or about August 7, 2013 at the jobsite located at 3153 S. Giles Avenue, Chicago, IL. - employees performing carpentry activities in a rehab were using a staircase where the landing was not equipped with guardrails, thereby exposing the employees to approximately eight (8) and half (1/2) feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339265845.