WHITERIVER, AZ —
OSHA Inspection: BIA-FORT APACHE AGENCY-FORESTRY DEVELOPMENT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BIA-FORT APACHE AGENCY-FORESTRY DEVELOPMENT in 2 W. ELM STREET, WHITERIVER, AZ 85941 (NAICS 115310). OSHA activity number 339274037.
Where did this inspection happen?
- Establishment
- BIA-FORT APACHE AGENCY-FORESTRY DEVELOPMENT
- Site address
- 2 W. ELM STREET
- City
- WHITERIVER
- State
- AZ
- ZIP
- 85941
- Mailing
- 2 W. ELM STREET, WHITERIVER, AZ 85941
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115310
- Employees
- 650
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) Power Saw Shop, Forestry Development, Fort Apache Agency, PO Box 560, Whiteriver, AZ 85491: On or about 01 August 2013, and at times prior thereto, the DeWalt 8 Inch Bench Grinder work rest was adjusted to a gap of 3/8 inch between the work rest and the abrasive wheel, exposing employees to hazards.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Powr Saw Shop, Fort Apache Agency, PO Box 560, Whiteriver, AZ 85491: On or about 1 August 2013, the DeWalt 8 inch bench grinder was adjusted to a gap of 1/2 inch between the tongue guard and the abrasive wheel periphery, exposing employees to hazards.
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Power Saw Shop, Fort Apache Agency, POB 560, Whiteriver, AZ 85491: On or about 1 August 2013, material and equipment were stored within three feet in front of the electrical panel box mounted on the northeast corner wall of the workshop, exposing employees to hazards.
Recent events (1)
- — Z (S) $0
More inspections at BIA-FORT APACHE AGENCY-FORESTRY DEVELOPMENT
WHITERIVER, AZ—2013-07-30 00:00:00
BIA-FORT APACHE AGENCY-FORESTRY DEVELOPMENT
View BIA-FORT APACHE AGENCY-FORESTRY DEVELOPMENT's full OSHA safety record →
More inspections in this industry (NAICS 115310)
SAN JUAN, PR—2026-07-16
U.S. DEPARTMENT OF AGRICULTURE-FOREST SERVICE
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
MARIENVILLE, PA—2026-06-30
UNITED STATES FOREST SERVICE
DIANA, TX—2026-06-26
AMIGO FORESTRY SERVICE, INC
RYDERWOOD, WA—2026-06-09
WA317991576 - C & V REFORESTATION INC
More inspections in AZ
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
CAMP VERDE, AZ—2026-07-14
CLIFF CASTLE CASINO & HOTEL
CAMP VERDE, AZ—2026-07-14
CLIFF CASTLE CASINO & HOTEL
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339274037.