Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: E ESQUIVEL ROOFING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of E ESQUIVEL ROOFING LLC in 3754 E. LASALLE STREET, COLORADO SPRINGS, CO 80909 (NAICS 238160). OSHA activity number 339274839.

Watch E Esquivel Roofing LLC — free Get an email when a new federal OSHA severe-injury report for E Esquivel Roofing LLC is published. One employer, no account, unsubscribe in one click.
Site address
3754 E. LASALLE STREET
City
COLORADO SPRINGS
State
CO
ZIP
80909
Mailing
36170 E US HIGHWAY 50, PUEBLO, CO 81006
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone:       1) On August 7, 2013, E Esquivel Roofing LLC did not protect its employees from falls in excess of 7 feet while engaged in a re-roof job.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface, the ladder did not extend at least 3 feet above the upper landing surface; or where this was not possible due to the ladders length,  the ladder was not secured at its top to a rigid support:     1) On August 7, 2013, E Esquivel Roofing LLC did not protect its employees from falls in excess of 7 feet while accessing the roof by a ladder.  The ladder was not extended at least 3 feet above the eave, nor was it secured.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 B01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.403(b)(1): The employer did not ensure that electrical equipment was free from recognized hazards that were likely to cause death or serious physical harm to employees:     1) On August 7, 2013, E Esquivel Roofing LLC did not protect its employees from electrical hazards, where a plug and cord extension outlet was hand wired into wiring from the buildings light fixtures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600