Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WALDI CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WALDI CONSTRUCTION, INC. in 740 PROSPECT AVE., PARK RIDGE, IL 60068 (NAICS 238160). OSHA activity number 339291957.

Watch Waldi Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Waldi Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
740 PROSPECT AVE.
City
PARK RIDGE
State
IL
ZIP
60068
Mailing
109 ESSEX RD., ELK GROVE VILLAGE, IL 60007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $1540.00 Reduced
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:         a) Employees were not provided with safe access to scaffolding from which they were required to work at an elevation of approximately 26 feet.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1926.451 F07

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2200.00 · Current $1100.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:      a) The employer did not ensure scaffolding provided for employee use was erected under the supervision and direction of a competent person qualified in scaffolding erection.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2200

1926.452 K01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $0.00 Reduced
29 CFR 1926.452(k)(1): Ladder jack scaffold platforms exceeded a height of 20 feet (6.1 m):           a) Employees were exposed to the hazard of falling approximately 26 feet during the performance of work from a ladder jack scaffold that exceeded the 20 foot maximum permissible height for ladder jack scaffolding.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1926.451 G01 I

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $1536.00 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:          a) Employees were exposed to the hazard of falling approximately 26 feet while working from ladder jack scaffolding without the benefit of fall protection.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1536
  • — Z (S) $3080

1926.501 B13

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):      a) Employees were exposed to the hazard of falling while working from a pitched roof having a ground to eave height of approximately 30 feet without the use of fall protection.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 K05

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2200.00 · Current $0.00 Reduced
CFR 1926.452(k)(5): Scaffold platforms were bridged on to another:        a) Employees were exposed to the hazard of falling approximately 26 feet where scaffold platforms were bridged together.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $2200

View WALDI CONSTRUCTION, INC.'s full OSHA safety record →