WALLINGFORD, CT —
OSHA Inspection: THERMOSPAS HOT TUB PRODUCTS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of THERMOSPAS HOT TUB PRODUCTS, INC. in 155 EAST ST, WALLINGFORD, CT 06492 (NAICS 326191). OSHA activity number 339306656.
Where did this inspection happen?
- Establishment
- THERMOSPAS HOT TUB PRODUCTS, INC.
- Site address
- 155 EAST ST
- City
- WALLINGFORD
- State
- CT
- ZIP
- 06492
- Mailing
- 155 EAST ST, WALLINGFORD, CT 06492
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326191
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1890.00 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: Facility: The employer did not ensure that the employees required to wear tight-fitting respirators were fit tested prior to wearing respirators and at least annually.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.134 K05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(5): Respiratory protection retraining was not conducted annually: Facility: The employer did not conduct respiratory protection training at least annually.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 II D
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1890.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(D): Refresher training was not provided to the operator when the operator was assigned to drive a different type of truck: Facility: The employer did not provide refresher training and re-evaluation of the operator's performance upon assigning to drive a different type of CAT powered industrial fork truck.
Recent events (2)
- — I (S) $1890
- — Z (S) $2700
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Facility: The employer did not evaluate each operator's performance at least every three years.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Facility: Portable fire extinguishers were not subjected to an annual maintenance check.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326191)
BRIDGEVILLE, PA—2026-06-26
KEYSTONE CULTURED SURFACES LLC.
CLEARWATER, FL—2026-05-20
ROYAL BATHS MANUFACTURING COMPANY
DOUBLE SPRINGS, AL—2026-05-08
AMERICAN FIBERGLASS PRODUCTS, INC.
NORTHUMBERLAND, PA—2026-04-03
STRONG INDUSTRIES INC.
LEXINGTON, TN—2026-03-12
BRAVO, INC.
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339306656.