OKLAHOMA CITY, OK —
OSHA Inspection: JOHNSTON WELDING AND FABRICATION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of JOHNSTON WELDING AND FABRICATION in 2 SANTA FE PLAZA, OKLAHOMA CITY, OK 73102 (NAICS 238990). OSHA activity number 339307464.
Where did this inspection happen?
- Establishment
- JOHNSTON WELDING AND FABRICATION
- Site address
- 2 SANTA FE PLAZA
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73102
- Mailing
- 14501 SW 104TH STREET, MUSTANG, OK 73064
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.351 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.351(b)(1): Arc welding or cutting cable(s) was not of the completely insulated, flexible type, capable of handling the maximum current requirements of the work in progress. On or about August 14, 2013, and times prior thereto, an employee was using a Lincoln Electric Ranger 250 GXT welder which had wires exposed on the electrode cable at the boot connection, exposing the employee to the hazard of electric shock.
Recent events (3)
- — F (S) $1000
- — C (S) $2800
- — Z (S) $2800
1926.351 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.351(b)(2): Welding cable(s) in use was not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected. On or about August 14, 2013, and at times prior thereto, an employee was using a Lincoln Electric Ranger 250 GXT welder which had repairs to the cable within 10 feet of the electrode holder, exposing the employee to the hazard of electric shock.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.351 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.351(b)(4): Welding cable(s) in use was in need of repair. On or about August 14, 2013, and times prior thereto, an employee was using a Lincoln Electric Ranger 250 GXT welder which had improper repair on the work cable, exposing the employee to the hazard of electric shock.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.352 D
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.352(d): Fire extinguishing equipment available in work area(s), where welding, cutting, or heating was being performed, was not maintained in a state of readiness for instant use. On or about August 14, 2013, and times prior thereto, there was no identifying tag or record of inspection for the fire extinguisher located on the Skyjack SJ111 scissor lift being used by an employee performing welding activities. This exposed the employee to hazards associated with fire. OR IN THE ALTERNATIVE... 29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers will be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.
Recent events (3)
- — F (O) $0
- — C (S) $2800
- — Z (S) $2800
1926.454 A03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1926.454(a)(3): The proper use of the scaffold, and the proper handling of materials on the scaffold. On or about August 14, 2013, a Skyjack DC Electric scissor lift was not being used properly at the worksite exposing the employee to tip-over and/or fall hazards.
Recent events (3)
- — F (S) $500
- — C (S) $2000
- — Z (S) $2000
More inspections in this industry (NAICS 238990)
ZEPHYRHILLS, FL—2026-07-14
PERIMETER SOLUTIONS GROUP FLORIDA, LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
NEW YORK, NY—2026-07-09
PALM INDUSTRIES LLC
EL PASO, TX—2026-07-09
RM CRANE & RIGGING LLC.
LAKEWOOD, WA—2026-07-08
WA317992018 - HARMON INC DBA HARMON SERVICE GLAZING INC
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339307464.