Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: CASUR CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CASUR CORPORATION in 277 BLEECKER ST, NEW YORK, NY 10014 (NAICS 236220). OSHA activity number 339311235.

Watch Casur Corporation — free Get an email when a new federal OSHA severe-injury report for Casur Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
CASUR CORPORATION
Site address
277 BLEECKER ST
City
NEW YORK
State
NY
ZIP
10014
Mailing
181 HILLSIDE AVENUE, WILLISTON PARK, NY 11596
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.       Location: 277 Bleecker St, New York, NY.      a) Employees were exposed to electrical shock while connecting an extension cord to an electrical conduit that was live and it lacked insulation at its loose end (the connection point); on or about 8/12/13.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.404 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.   Location: 277 Bleecker St, New York, NY.   a) Employer did not ensure that the Bosch hammer drill powered by an extension cord was provided with a GFCI or an assured equipment program; on or about 8/14/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.      Location: 277 Bleecker St, New York, NY.   a) Employer failed to ensure that employees were protected from falling while walking and/or working near an unprotected edge at the site. The employees were exposed to a potential fall of up to approximately 6 ft. to the floor below; on or about 8/12/13.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.503 C

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(c): "Retraining." When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer shall retrain each such employee. Circumstances where retraining is required include, but are not limited to, situations where:    Location: 277 Bleecker St, New York, NY.  a) Employer failed to ensure that employees were protected from falling while walking and/or working near an unprotected edge at the site. The employees were exposed to a potential fall of up to approximately 6 ft. to the floor below.  Fall protection re-training is required; on or about 8/12/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.850 A

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1926.850(a): Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed.       Location: 277 Bleecker St, New York, NY.     a) Employer failed to produce evidence in writing that an engineering survey was performed prior to allowing employees to commence demolition operations at the site; on or about 8/12/13.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.850 C

Serious Gravity 10 4 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.850(c): All electric, gas, water, steam, sewer, and other service lines shall be shut off, capped, or otherwise controlled, outside the building line before demolition work is started. In each case, any utility company which is involved shall be notified in advance.    Location: 277 Bleecker St, New York, NY.   a) Employer failed to shut off/cap/controlled the electrical service prior to the start of demolition operations; on or about 8/12/13.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339311235.