CANANDAIGUA, NY —
OSHA Inspection: PROCTOR ROOFING
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PROCTOR ROOFING in 294 MAIN STREET, CANANDAIGUA, NY 14424 (NAICS 238160). OSHA activity number 339316077.
Where did this inspection happen?
- Establishment
- PROCTOR ROOFING
- Site address
- 294 MAIN STREET
- City
- CANANDAIGUA
- State
- NY
- ZIP
- 14424
- Mailing
- 4850 WEST SWAMP ROAD, STANLEY, NY 14561
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: a) At the jobsite, on the roof, on or about 7/31/13: Employees were working on a 9:12 pitch roof, with an approximate ground to eave height of 30 feet from ground without fall protection. Abatement certification must be submitted for this item.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) At the jobsite, at the front of the building, on or about 7/31/13: Employees were accessing a 9:12 pitch roof, with an approximate ground to eave height of 30 feet where the ladder used did not extend at least 3 feet above the upper landing. b) At the jobsite, at the front of the building, on or about 7/31/13: Employees were accessing a 4:12 pitch roof, with an approximate ground to eave height of 15 feet where the ladder used did not extend at least 3 feet above the upper landing. c) At the jobsite, on the Perry Place side of the building, on or about 7/31/13: Employees were accessing a 9:12 pitch roof, with an approximate ground to eave height of 30 feet where the ladder used did not extend at least 3 feet above the upper landing. d) At the jobsite, on the Perry Place side of the building, on or about 7/31/13: Employees were accessing a 9:12 pitch roof, with an approximate ground to eave height of 30 feet where the ladder used did not extend at least 3 feet above the upper landing. Abatement certification must be submitted for this item.
Recent events (1)
- — Z (S) $2800
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339316077.