CHATHAM, NY —
OSHA Inspection: TODD SHIELDS, BUILDER-FRAMER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TODD SHIELDS, BUILDER-FRAMER in 15-17 MAIN STREET, CHATHAM, NY 12037 (NAICS 238130). OSHA activity number 339327074.
Where did this inspection happen?
- Establishment
- TODD SHIELDS, BUILDER-FRAMER
- Site address
- 15-17 MAIN STREET
- City
- CHATHAM
- State
- NY
- ZIP
- 12037
- Mailing
- 255 KONIG ROAD, GHENT, NY 12075
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: (a) Front of the Building - on or about August 20, 2013 - guardrails or other acceptable means of fall protection were not provided on the elevated scaffold platform. Scaffold deck elevation was approximately 17 feet, 6 inches to the asphalt pavement.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) Front of the Building - on or about August 20, 2013 - the employer did not train the employees that were performing work from an elevated scaffold deck in the nature of fall hazards with this type of a scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: (a) Second Story Balcony, Front of the Building - on or about August 20, 2013 - the height of the top rail of the guardrail exceeded the maximum requisite height. Balcony elevation was approximately 9 feet from the ground.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.502 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: (a) Second Story Balcony, Front of the Building - on or about August 20, 2013 - no midrail was installed on the guardrail system. Balcony elevation was approximately 9 feet to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Second Story Balcony, Front of the Building - on or about August 20, 2013 - the employer did not provide a fall protection training program to the employees that were performing exterior framing to the building. Elevation was approximately 9 feet from balcony to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339327074.