1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: EPIC ENTERPRISES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EPIC ENTERPRISES, INC. in 11 COPELAND DRIVE, AYER, MA 01432 (NAICS 312111). OSHA activity number 339361677.

Watch Epic Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Epic Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11 COPELAND DRIVE
City
AYER
State
MA
ZIP
01432
Mailing
11 COPELAND DRIVE, AYER, MA 01432
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312111
Employees
147
Ownership type
A

8 citations on file for this inspection.

1910.146 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2700.00 · Current $1350.00 Reduced
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  (a) Location - Wastewater pit: On or about 8/23/13, the wastewater pit was not labeled as a confined space.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2700

1910.147 C07 I B

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2025.00 · Current $1013.00 Reduced
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:  (a) Location - Establishment: On or about 8/23/13, machine operators were not provided lockout/tagout training to protect them from hazardous energy.
Recent events (2)
  • — I (S) $1012.5
  • — Z (S) $2025

1910.219 F03

Serious Gravity 5 3 instances 10 exposed
Issued
Penalty
Initial $2700.00 · Current $1350.00 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:  (a) Location - Production: On or about 8/23/13, the chain drives on the Simplimatic depalletizing machines were not equipped with guards.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2700

1904.29 B03

Other-than-serious 3 instances 147 exposed
Issued
Penalty
Initial $675.00 · Current $338.00 Reduced
29 CFR 1904.29(b)(3): Each recordable injury or illness was not recorded on the OSHA 300 Log and 301 Incident Report within seven calendar days of receiving information that a recordable injury or illness has occurred:  (a) Location - Establishment: On or about 8/23/13, injuries resulting in lost work days were not entered on the OSHA Log within 7 days.
Recent events (2)
  • — I (O) $337.5
  • — Z (O) $675

1910.151 C

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $574.00 · Current $287.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) Location - Battery charging area: On or about 8/23/13, the emergency eye wash station was not functioning.
Recent events (2)
  • — I (O) $287
  • — Z (O) $574

1910.178 L04 III

Other-than-serious 9 instances 50 exposed
Issued
Abate by
Penalty
Initial $675.00 · Current $338.00 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  (a) Location - Establishment: On or about 8/23/13, employees operating powered industrial trucks were not evaluated every three years to ensure that they could operate safely.
Recent events (2)
  • — I (O) $337.5
  • — Z (O) $675

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $675.00 · Current $338.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a) Location - Corridor: On or about 8/23/13, a powered industrial truck was parked in front of the electrical panel.
Recent events (2)
  • — I (O) $337.5
  • — Z (O) $675

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) Location - Filler room: On or about 8/23/13, a receptacle was not equipped with a cover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View EPIC ENTERPRISES, INC.'s full OSHA safety record →