WESTFIELD, MA —
OSHA Inspection: SOMMER ELECTRIC, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SOMMER ELECTRIC, INC in 127 EAST MOUNTAIN ROAD, WESTFIELD, MA 01085 (NAICS 238210). OSHA activity number 339363228.
Where did this inspection happen?
- Establishment
- SOMMER ELECTRIC, INC
- Site address
- 127 EAST MOUNTAIN ROAD
- City
- WESTFIELD
- State
- MA
- ZIP
- 01085
- Mailing
- 60 PRINTWORKS DR., ADAMS, MA 01220
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.652 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): (a) Location: 127 East Mountain Road, Westfield, MA: On or about August 30, 2013 two employees installing a storm drain from an existing building were not protected from cave-ins while working in a trench that was approximately 8.5 feet deep. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.651 J02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: (a) Location: 127 East Mountain Road, Westfield, MA: On or about August 30, 2013 two employees working inside a trench approximately 8.5 feet deep installing a storm drain were exposed to cave-in hazards posed by spoil piles placed approximately 12 inches from the edge of the excavation. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.651 C02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) Location: 127 East Mountain Road, Westfield, MA: On or about August 30, 2013 two employees working inside an 8.5 feet deep trench installing a storm drain were not provided a safe means of egress or exit exposing employees to fall hazard inside the trench. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.651 K01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: (a) Location: 127 East Mountain Road, Westfield, MA: On or about August 30, 2013 two employees working inside a trench approximately 8.5 feet deep installing a storm drain were exposed to cave-ins. A daily inspection by a competent person had not been performed in accordance with this subpart. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at SOMMER ELECTRIC, INC
ADAMS, MA—1999-10-15 00:00:00
SOMMER ELECTRIC, INC.
View SOMMER ELECTRIC, INC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
PARKVILLE, MD—2026-07-15
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15
EDGE ELECTRICAL SYSTEMS, LLC
LAYTON, UT—2026-07-14
LYNN WOODWARD ELECTRIC LLC
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
ANNAPOLIS, MD—2026-07-14
J.M. MULLEN ELECTRICAL SERVICES, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339363228.