Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DEMATTO BUILDERS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DEMATTO BUILDERS LLC in BLDG 310 QUARRY KNOLL AVE, GREENWICH, CT 06830 (NAICS 238170). OSHA activity number 339363251.

Watch Dematto Builders LLC — free Get an email when a new federal OSHA severe-injury report for Dematto Builders LLC is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 310 QUARRY KNOLL AVE
City
GREENWICH
State
CT
ZIP
06830
Mailing
341 HILLSIDE AVE, HARTFORD, CT 06106
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
9
Ownership type
A

6 citations on file for this inspection.

1926.304 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:Note:  See paragraph (i)(1) of this section for additional requirements for hand-fed crosscut table saws.   Jobsite:  The portable table saw that was used by employees to rip/cut trim boards was not guarded with a hood that completely enclosed the portion of the blade above the table.
Recent events (3)
  • — F (S) $2000
  • — C (S) $2000
  • — Z (S) $2000

1926.451 C02

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $2000.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:
Recent events (3)
  • — F (S) $2000
  • — C (S) $1600
  • — Z (S) $1600

1926.451 F07

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.
Recent events (3)
  • — F (S) $0
  • — C (S) $1600
  • — Z (S) $1600

1926.452 J02

Serious Gravity 5 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    Jobsite; rear of building and left side of building:  The pump jack scaffold that employees were working from was not braced or secured at the bottom of the scaffold poles.
Recent events (3)
  • — F (S) $0
  • — C (S) $1600
  • — Z (S) $1600

1926.451 G01 VII

Deleted Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.   Jobsite; rear of building and left side of building:  The pump jack scaffold that the employee was working from was not erected under the supervision of a person competent in scaffold erection.
Recent events (3)
  • — J (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  Jobsite; rear of building and left side of building:  The extension ladders that were used to gain access to the working platforms of the pump jack scaffolds did not have its side rails extended 3 feet above the landing surface.
Recent events (3)
  • — F (S) $1600
  • — C (S) $1600
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339363251.