Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HYBRID PLASTICS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of HYBRID PLASTICS in 55 W.L. RUNNELS INDUSTRIAL DRIVE, HATTIESBURG, MS 39401 (NAICS 325211). OSHA activity number 339363491.

Watch Hybrid Plastics — free Get an email when a new federal OSHA severe-injury report for Hybrid Plastics is published. One employer, no account, unsubscribe in one click.
Establishment
HYBRID PLASTICS
Site address
55 W.L. RUNNELS INDUSTRIAL DRIVE
City
HATTIESBURG
State
MS
ZIP
39401
Mailing
55 W.L. RUNNELS INDUSTRIAL DRIVE, HATTIESBURG, MS 39401
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.101 B

Serious Gravity 1 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, Section 3.4.4, Compressed Gas Association, Inc. Pamphlet P-1-1965,as incorporated by reference as specified in Sec. 1910.6. - Compressed gas cylinder(s) in use were not properly supported to prevent them from being knocked over:   (a) Storage room - On or about August 28, 2013 employees were exposed to unrestrained compressed nitrogen and nitrogen-hydrogen mix cylinders.  (b) Lab - On or about August 28, 2013 employees were exposed to unrestrained compressed gas cylinders
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.134 F

Serious Gravity 5 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.134(f): Fit testing. This paragraph requires that, before an employee may be required to use any respirator with a negative or positive pressure tight-fitting facepiece, the employee must be fit tested with the same make, model, style, and size of respirator that will be used:   (a) Site wide - On or about August 28, 2013 employees were using half-face tight-fitting respirator without being fit tested.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area:   (a) Site wide - On or about August 28, 2013 employee working at site and had not been provided information and training as requried by the standard.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339363491.