OSHA Inspection: PERENNIAL ENERGY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PERENNIAL ENERGY, LLC in 1375 COUNTY ROAD 8690, WEST PLAINS, MO 65775 (NAICS 333999). OSHA activity number 339365264.

Watch Perennial Energy, LLC — free Get an email when a new federal OSHA severe-injury report for Perennial Energy, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1375 COUNTY ROAD 8690
City
WEST PLAINS
State
MO
ZIP
65775
Mailing
1375 COUNTY ROAD 8690, WEST PLAINS, MO 65775
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
32
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2083.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  (a) Shop: Employees were exposed to electrical hazards as there were no machine specific Lockout Tagout procedures for machinery that was hardwired in, and had more than one source of energy, for equipment such as, but not limited to, the Hyperthem Plasma Cutter.   Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2975

1910.178 P01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  (a) Manufacturing:  The Clark forklift did not have an operating horn and it was not taken out of service.   Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.253 B04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  (a) Shop/Manufacturing:  Employees were exposed to fire hazards as an oxygen cylinder and an acetylene cylinder were stored together.  Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) Shop/Manufacturing: Employees were exposed to electrical hazards as the Milwaukee Heavy Duty Sander was not grounded as the grounding pin was absent.   Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.305 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.305(f)(1): All conductors used for general wiring were not insulated unless otherwise permitted in this subpart.  (a) Shop/Manufacturing: Employees were exposed to electrical hazards as the Millermatic 251 Wire Welder had a cut in the insulation for the electrical power cord.  (b) Shop/Manufacturing: Employees were exposed to electrical hazards as the Schumacher Fast Charger had a cut in the insulation for the electrical power cord.  Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785