Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DOUBLE K. ELECTRIC CORP.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DOUBLE K. ELECTRIC CORP. in 3920 PAULDING AVE, BRONX, NY 10466 (NAICS 238210). OSHA activity number 339390049.

Watch Double K. Electric Corp. — free Get an email when a new federal OSHA severe-injury report for Double K. Electric Corp. is published. One employer, no account, unsubscribe in one click.
Site address
3920 PAULDING AVE
City
BRONX
State
NY
ZIP
10466
Mailing
247-03 JERICHO TURNPIKE, BELLEROSE, NY 11426
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:    On or about 9/4/2013, Paulding Ave.    a) The employees were not provided safety and health training as required by the standard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.404 B01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductor:    On or about 9/4/2013, Paulding Ave.    a) The employees were setting pipes and using power tools without a ground fault circuit interrupter.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.1052 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    On or about 9/4/2013, South Stairs    a) The stairs were enclosed on both sides and were missing a handrail.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1052 C01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76cm), whichever is less, did not have one stairrail system along each unprotected side or edge:    Note: When the top edge of a stairrail system also serves as a handrail, paragraph (c)(7) of this section applies.    On or about 9/4/2013, Front Stairs and Stair Tower     a) Both sets of stairs were missing a stairrail system, exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1052 C12

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems:     Guardrail system criteria are contained in subpart M of this part.    On or about 9/4/2013, Stair Tower    a) There were two unprotected stair landings exposing the employees to an 11' to 22' fall hazard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View DOUBLE K. ELECTRIC CORP.'s full OSHA safety record →