BARRONETT, WI —
OSHA Inspection: WISCONSIN STRUCTURAL STEEL COMPANY
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WISCONSIN STRUCTURAL STEEL COMPANY in HIGHWAY 63 NORTH, BARRONETT, WI 54813 (NAICS 332312). OSHA activity number 339393092.
Where did this inspection happen?
- Establishment
- WISCONSIN STRUCTURAL STEEL COMPANY
- Site address
- HIGHWAY 63 NORTH
- City
- BARRONETT
- State
- WI
- ZIP
- 54813
- Mailing
- PO BOX 38, BARRONETT, WI 54813
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 93
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 D
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.134(d): Employer did not evaluate respiratory hazard(s) in the workplace, to identify relevant workplace and user factors, and base respirator selections on these factors. (a): Welding operations; zinc oxide fumes and other fumes are released due to welding and/or cutting on galvanize steel and/or painted steel without an employer evaluation of the respiratory hazards of the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $2700
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was required to use the respirator in the workplace or fit tested. Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. (a) Welding operations; employees are required to wear respirators during normal work operations when conducting continuous welding, painting operations and/or other activities determined by the supervisor without completing a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Welding operations; employees are required to wear respirators during normal work operations when conducting continuous welding, painting operations and/or other activities determined by the supervisor without being properly fit tested.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $1890.00
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): (a): Welding operations; Employees are exposed to Iron Oxide fumes above the OSHA PEL due to the failure of the employer to implement administrative, engineering or protective equipment controls. Such as, but not limited to; limits to employee welding, rotating schedules, additional ventilation or local exhaust ventilation (LEV) and/or respiratory protection.
Recent events (2)
- — I (O) $1890
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $1890.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met as identified in 29 CFR 1910.252(c)(1)(iv). (a) Welding operations; The Hazardous communication program does not include specific training related to materials used or released to the atmosphere when welding and cutting; including, but not limited to metal fume fever, adverse effects to central nervous system, nausea, kidney damage, respiratory damage, shortness of breath, general weakness, chronic cough, and/or irritation to the eyes, nose and throat.
Recent events (2)
- — I (O) $1890
- — Z (S) $2700
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339393092.