BETHLEHEM, PA —
OSHA Inspection: DIEFENDERFER CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DIEFENDERFER CONSTRUCTION in E. GEOPP ST. AND LINDEN STREET, BETHLEHEM, PA 18017 (NAICS 238160). OSHA activity number 339407066.
Where did this inspection happen?
- Establishment
- DIEFENDERFER CONSTRUCTION
- Site address
- E. GEOPP ST. AND LINDEN STREET
- City
- BETHLEHEM
- State
- PA
- ZIP
- 18017
- Mailing
- 340 S. PENN DIXIE ROAD, BATH, PA 18014
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation. a) S. Geopp and Linden Street - on or about September 5, 2013, the belt and pulley on a portable air compressor were not guarded to prevent employees from coming into contact with the moving parts.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. a) E. Geopp and Linden Street - on or about September 5, 2013, employees using a pneumatically powered Senco staple gun to secure roofing materials were not utilizing safety glasses.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) E. Geopp and Linden Street - on or about September 5, 2013, the ladder jack scaffold erected 20.5 feet above ground was not provided with guardrails.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) E. Geopp and Linden Street - on or about September 5, 2013, an employee engaged in residential roofing on a 11/12 pitch roof, 20.5 feet above grade, was not utilizing fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) E. Geopp and Linden Street - on or about September 5, 2013, the ladder used to gain access to the 9.5 foot roof did not extend at least three feet above the upper landing surface.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. a) E. Geopp and Linden Street - on or about September 5, 2013, the ladder used to access the roof, 20.5 feet above grade, was bent at the top of the ladder and not taken out of service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339407066.