PARK RIDGE, IL —
OSHA Inspection: PRO-PAT CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRO-PAT CORPORATION in 14 WISNER STR., PARK RIDGE, IL 60068 (NAICS 238160). OSHA activity number 339409328.
Where did this inspection happen?
- Establishment
- PRO-PAT CORPORATION
- Site address
- 14 WISNER STR.
- City
- PARK RIDGE
- State
- IL
- ZIP
- 60068
- Mailing
- 619 WOODHAVEN DR., MUNDELEIN, IL 60060
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 22 feet above the ground. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Ladder used by employees to gain access to the working area did not have its side rails extended at least 3 feet above the landing surface. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339409328.