Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PJ SIDING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PJ SIDING in 332-334 WHITTIER AVENUE, SYRACUSE, NY 13204 (NAICS 238160). OSHA activity number 339410680.

Watch PJ Siding — free Get an email when a new federal OSHA severe-injury report for PJ Siding is published. One employer, no account, unsubscribe in one click.
Establishment
PJ SIDING
Site address
332-334 WHITTIER AVENUE
City
SYRACUSE
State
NY
ZIP
13204
Mailing
100 NORTHWOOD WAY, CAMILLUS, NY 13031
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1800.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) 332-334 Whittier Avenue, Syracuse NY - On or about 11 September, 2013 - Employees were working on a residential roof above 6 feet without the use of personal fall protection.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1926.502 D15

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  a) 332-334 Whittier Avenue, Syracuse NY - On or about 11 September, 2013 - Employees were working on a residential roof using only one(1) anchor point for 2 employees fall protection harnesses.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.453 B02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.453(b)(2)(v): 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:    a) 332-334 Whittier Avenue, Syracuse NY - On or about 11 September, 2013 - Employees were working in an elevated aerial lift without the use of a safety harness.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339410680.