Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DENT DEPOT, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DENT DEPOT, LLC in 7105 N. MAY, OKLAHOMA CITY, OK 73116 (NAICS 811121). OSHA activity number 339413510.

Watch Dent Depot, LLC — free Get an email when a new federal OSHA severe-injury report for Dent Depot, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DENT DEPOT, LLC
Site address
7105 N. MAY
City
OKLAHOMA CITY
State
OK
ZIP
73116
Mailing
7105 N. MAY, OKLAHOMA CITY, OK 73116
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
8
Ownership type
A

9 citations on file for this inspection.

1910.107 C06

Serious Gravity 5 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for     Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:     Shop: On or about September 11, 2013, the employer allowed electrical equipment not rated for Class I Group D locations to be used inside the spray booth and paint storage and mixing areas exposing employees to the hazard of explosion.      a) A 220 electrical outlet not rated for Class I Group D locations was used in the spray booth. The outlet was not explosion proof.      b) A heat lamp not rated for Class I Group D locations was used in the spray booth. The lamp was missing the ground pin.      c) Electrical equipment used in the paint storage and mixing area was not rated for Class I Group D locations. Electrical equipment was not rated as explosion proof.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.107 E09

Serious Gravity 5 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(e)(9): Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity.  Shop: On or about September 11, 2013, the employer did not ensure the drum being used to collect waste paints and thinners was grounded exposing employees to the hazard of explosion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer:    Shop: On or about September 11, 2013, the employer required employees to wear respiratory protection without establishing and implementing a written respiratory protection program exposing employees to hazards such as, but not limited to, contact-with hazardous chemicals.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.134 D03 III B 2

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:    Shop: On or about September 11, 2013, the employer did not implement a change schedule for respirator cartridges used by employees while painting finished products, exposing employees to the hazard of chemical exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:    Shop: On or about September 11, 2013, the employer did not provide a respiratory medical evaluation to employees before requiring them to wear respiratory protection , exposing employees to the hazard of chemical exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph:    Shop: On or about September 11, 2013, the employer did not provide a respiratory protection fit test to employees before requiring them to wear respiratory protection exposing employees to hazards such as, but not limited to, contact-with hazardous chemicals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    Shop: On or about September 11, 2013, the employer did not ensure employees stored respiratory protection to protect it from damage and contamination exposing employees to the hazard of contact with hazardous chemicals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:   Shop: On or about September 11, 2013, the employer has not provided employees required to use respiratory protection with comprehensive and effective training, exposing employees to the hazard of chemical exposure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    Shop: On or about September 11, 2013, the employer did not develop and implement a written hazard communication program exposing employees to the hazard of contact with hazardous components of chemicals such as, but not limited to, Transtar Autobody Technologies EZ Sand 2K Acrylic Urethane Primer 6401, Transtar Autobody Technologies Extra Solids Activator Spot Panel 6874 and PPG Industries Deltron Mixing Bases.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339413510.