OSHA Inspection: JOY PROCESS MECHANICAL A DIVISION OF THE EDWARD JOY COMPANY

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of JOY PROCESS MECHANICAL A DIVISION OF THE EDWARD JOY COMPANY in 709 NORTH MAIN STREET, CANASTOTA, NY 13032 (NAICS 238290). OSHA activity number 339413999.

Watch JOY Process Mechanical A Division OF THE Edward JOY Company — free Get an email when a new federal OSHA severe-injury report for JOY Process Mechanical A Division OF THE Edward JOY Company is published. One employer, no account, unsubscribe in one click.
Site address
709 NORTH MAIN STREET
City
CANASTOTA
State
NY
ZIP
13032
Mailing
PO BOX 338, EAST SYRACUSE, NY 13057
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
20
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $7000.00
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazardous atmospheres while working in a permit required confined space:      a) On or about 9/11/2013, Canastota Waste Water Treatment Facility:  Employee performing welding and cutting operations inside of a "Methane Collection Dome"  was exposed to a hazardous atmosphere caused by Methane gas.      Among other methods, a feasible abatement method to correct this hazard is to comply with American National Standards Institute ANSI/ASSE Z117.1-2009 ,Safety Requirements for Confined Spaces.  Including, but not limited to:         1) Provide a confined space survey as referenced in Section 3.1       2) Provide a hazard evaluation as referenced in Section 3.3        3) Implement a written confined space program as referenced in Section 3.6        4) Provide training and verification including, but not limited to use of meters, retrieval systems, and contents            of the confined space program as referenced in Section 15      5) Conduct atmospheric testing prior to entry into the confined space as referenced in Section 6.1      Abatement Documentation is required for this item.
Recent events (3)
  • — J (S) $7000
  • — C (S) $4900
  • — Z (S) $4900

1926.353 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $0.00 Reduced
29 CFR 1926.353(b)(1): General mechanical or local exhaust ventilation meeting the requirements of paragraph (a) of 29 CFR 1926.353 was not provided where welding, cutting, or heating was performed in a confined space and employees were not otherwise protected:    a) On or about 9/11/2013, Canastota Waste Water Treatment Facility:  Employee performing welding inside of a permit required confined space was not provided with adequate ventilation.      Abatement Documentation is required for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $4900
  • — Z (S) $4900

1926.353 B03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.353(b)(3): Where a welder must enter a confined space through a manhole or other small opening, means were not provided for quickly removing him in case of an emergency:     a) On or about 9/11/2013, Canastota Waste Water Treatment Facility:  Employee performing cutting and welding inside of a permit required confined space with a three foot diameter opening was not provided with a retrieval system.         Abatement Documentation is required for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.21 B06 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3000.00 Reduced
29 CFR 1926.21(b)(6)(i): Employees required to enter into confined or enclosed spaces were not instructed as to the nature of the hazards involved, the necessary precautions to be taken, and in the use of protective and emergency equipment required:     a) On or about 9/11/2013, Canastota Waste Water Treatment Facility:  Employee performing welding and cutting operations inside of a permit required confined space was not provided with training regarding the recognition, avoidance and management of hazards associated with work inside of a confined space.      Abatement Documentation is required for this item.
Recent events (3)
  • — J (O) $3000
  • — C (S) $4900
  • — Z (S) $4900

1926.59

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.59:  An employer engaged in construction activities did not comply with the requirements set forth in Part 1910, Section 1200, Hazard Communication:     a) On or about 9/11/2013, Canastota Waste Water Treatment Facility:  Employees exposed to materials such as, but not limited to Methane were not provided with training in regards to the hazards and properties associated with them, and were not provided with access to a Material Safety Data Sheet for Methane.        Abatement certification is required for this item.
Recent events (3)
  • — J (O) $0
  • — C (S) $0
  • — Z (S) $0