FORT LAUDERDALE, FL —
OSHA Inspection: DRUCTOR CONSTRUCTION, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DRUCTOR CONSTRUCTION, INC in 416 SW 11TH AVENUE, FORT LAUDERDALE, FL 33312 (NAICS 238110). OSHA activity number 339420721.
Where did this inspection happen?
- Establishment
- DRUCTOR CONSTRUCTION, INC
- Site address
- 416 SW 11TH AVENUE
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33312
- Mailing
- 1007 N. FEDERAL HWY #12, FORT LAUDERDALE, FL 33304
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 9/19/2013, at the above addressed job site, an employee was installing veneer brick on the exterior structure of a residential home and was exposed to a 7 ' fall hazard while working from a one-tier scaffold that was not fully planked.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 C02
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 9/19/2013, at the above addressed job site, the employer did not ensure scaffolds were erected with base plates and mud sills. Instance 1: An employee working from a one-tier scaffold without baseplates and mudsills. Instance 2: An employee using a two-tier scaffold to access a roof did not have baseplates or mudsills.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 C02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: On or about 9/19/2013, at the above addressed job site, the employer did not ensure scaffolds were supported with the correct components to keep the scaffold level. Instance 1: An employee installing veneer brick on the exterior structure while working from a one-tier scaffold supported with cement block units. Instance 2: An employee used a two-tier scaffold supported with cement block units to access a roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 9/19/2013, at the above addressed job site, an employee was exposed to a fall hazard of approximately 13 feet while working at a construction site. Instance 1: An employee on a 4:12 pitch roof applying grout between the bricks without fall protection equipment. Instance 2: An employee using a walking platform without guard rails to access the roof.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1053 B13
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: On or about 9/19/2013, at the above addressed job site, an employee was exposed to a fall hazard of approximately 6 feet while using the top step of an A-Frame ladder to descend from a one-tier scaffold.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
More inspections in this industry (NAICS 238110)
FREELAND, WA—2026-07-10
WA317992031 - NORTH RIVER CONCRETE PUMPING LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
WEBSTER, TX—2026-07-09
ZITRO CONCRETE CONSTRUCTION LLC
CHICAGO, IL—2026-07-09
GOEBEL FORMING, LLC
SAN ANTONIO, TX—2026-07-08
URBAN CONCRETE CONTRACTORS LTD
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339420721.