Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JAFTECH MANUFACTURING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JAFTECH MANUFACTURING, INC. in 6399 142ND AVE. N., STE 118, CLEARWATER, FL 33760 (NAICS 335122). OSHA activity number 339424467.

Watch Jaftech Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Jaftech Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6399 142ND AVE. N., STE 118
City
CLEARWATER
State
FL
ZIP
33760
Mailing
6399 142ND AVE. N., STE 118, CLEARWATER, FL 33760
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
Employees
5
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a struck-by and caught-in hazards.   a. On or about 09/24/2013, at the facilities - the storage racks along the walls were not anchored to the floor, exposing the employees to a struck-by and caught-in hazards.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    a. On or about 09/24/2013, at the facilities - a flexible cord that was used to connect a powered saw was repaired using black electrical tape.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a. On or about 09/24/2013, at the facilities - fire extinguishers were not readily identified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 I

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners:Note:  Temporary electrical power and lighting installation(s) may only be used as specified by 1910.305(a)(2)(i)(A) through 1910.305(a)(2)(i)(C).   a. On or about 09/24/2013, at the facilities - temporary electrical cable was used to energize fixed equipment, in that, it was hard wire directly into the junction box and was not protected with the use of conduit.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   a. On or about 09/24/2013, at the facilities - covers to a junction box were not installed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339424467.