Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIZDAR BROTHERS SEWER & CONSTRUCTION CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIZDAR BROTHERS SEWER & CONSTRUCTION CO., INC. in 1001 PINE ST., SAINT LOUIS, MO 63101 (NAICS 238220). OSHA activity number 339432080.

Watch Dizdar Brothers Sewer & Construction CO., INC. — free Get an email when a new federal OSHA severe-injury report for Dizdar Brothers Sewer & Construction CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1001 PINE ST.
City
SAINT LOUIS
State
MO
ZIP
63101
Mailing
4501 OLEATHIA AVENUE, SAINT LOUIS, MO 63116
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
12
Ownership type
A

5 citations on file for this inspection.

1926.403 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1122.00 · Current $336.00 Reduced
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:        a) Dizdar Brothers Sewer & Construction Co., Inc. @ 1001 Pine St., St. Louis, MO 63101: On and before 9/30/13, the employer did not ensure that flexible cord sets (extension cords) were free from recognized hazards. One of the two flexible cord sets observed on the site was damaged. This condition exposed employees to electrical shock hazards.
Recent events (3)
  • — F (S) $336
  • — C (S) $1122
  • — Z (S) $1122

1926.404 F06

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:            a) Dizdar Brothers Sewer & Construction Co., Inc. @ 1001 Pine St., St. Louis, MO 63101: On and before 9/30/13, the employer did not ensure that the forced air fan, which was used to ventilate the excavation, had a permanent path to ground. The flexible cord that was used to power the fan was missing the ground pin. This condition exposed employees to electrical shock hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.405 A02 II I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:     a) Dizdar Brothers Sewer & Construction Co., Inc. @ 1001 Pine St., St. Louis, MO 63101: On and before 9/30/13, the employer did not ensure that the flexible cord set that was used to power the forced air fan was free from damage. The outer insulation was ripped along a short length of the cord set and thereby, exposed the inner conductors. This condition exposed employees to electrical shock hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:              a) Dizdar Brothers Sewer & Construction Co., Inc. @ 1001 Pine St., St. Louis, MO 63101: On and before 9/30/13, the employer did not ensure that the flexible cord set that was used to power the forced air fan was free from damage. The strain relief for the female-end of the cord was damaged, so that the outer insulation was pulled away from the plug and thereby, exposed the inner conductors. This condition exposed employees to electrical shock hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1496.00 · Current $449.00 Reduced
29 CFR 1926.1053(b)(1): The employer did not ensure that when portable ladders were used to access the upper landing of the building the ladder side rails were not extended at least 3ft above the upper landing surface:       a) Dizdar Brothers Sewer & Construction Co., Inc. @ 1001 Pine St., St. Louis, MO 63101: On and before 9/30/13, the employer did not ensure that a ladder that was used to access an excavation extended at least 3ft above the upper landing surface. Employees utilized a 14ft ladder for access to a 14ft excavation. This condition exposed employees to a fall hazard of 14ft while entering and exiting the excavation.
Recent events (3)
  • — F (S) $449
  • — C (S) $1496
  • — Z (S) $1496

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339432080.