HOUSTON, TX —
OSHA Inspection: TOOL-FLO MANUFACTURING INC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of TOOL-FLO MANUFACTURING INC in 7803 HANSEN RD, HOUSTON, TX 77061 (NAICS 333512). OSHA activity number 339433120.
Where did this inspection happen?
- Establishment
- TOOL-FLO MANUFACTURING INC
- Site address
- 7803 HANSEN RD
- City
- HOUSTON
- State
- TX
- ZIP
- 77061
- Mailing
- 7803 HANSEN RD, HOUSTON, TX 77061
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333512
- Employees
- 180
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the facility, on or about October 16, 2013, procedures were not utilized for the control of hazardous energy when servicing a Cosen band saw, Model AH-250H.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $4725.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) At the facility, where annnual inspections of the energy control procedures were not performed. Employees perform maintenance and servicing activities on machinery such as, but not limited to, the Cosen bandsaw, Model AH-250H.
Recent events (2)
- — I (S) $4725
- — Z (S) $6300
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) At the facility, where aurthorized employees had not received energy control training. Authorized employees perform maintenance and servicing tasks, such as, but not limited to, changing the blade on a Cosen bandsaw, model AH-250H.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1910.147 D02
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $5250.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) At the facility, on or about October 16, 2013, where a Cosen bandsaw, Model AH-250H, was not turned off during maintenance and servicing activities.
Recent events (2)
- — I (S) $5250
- — Z (S) $7000
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) At the facility, on or about October 16, 2013, where energy to a Cosen bandsaw, Model AH-250H, was not isolated during maintenance and servicing activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) At the facility, on or about October 16, 2013, where a lockout device had not been attached to the energy isolating device of a Cosen bandsaw, Model AH-250H, during servicing and maintenance activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 333512)
HATTON, KY—2025-09-25
68430 - CAPITAL CITY TOOL INC
HOUSTON, TX—2025-06-17
MAZAK CORPORATION
MINNEAPOLIS, MN—2025-06-11
109309 - DECONICK INC DBA OPA MACHINING TECHNOLOGY
RED WING, MN—2025-02-13
108783 - MACTECH INC
MARION, NC—2024-12-04
157895 - TOOLCO INDUSTRIAL CORPORATION
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source