Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JMA PAINTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JMA PAINTING in 8380 N. BOOTH, KANSAS CITY, MO 64158 (NAICS 238320). OSHA activity number 339437865.

Watch JMA Painting — free Get an email when a new federal OSHA severe-injury report for JMA Painting is published. One employer, no account, unsubscribe in one click.
Establishment
JMA PAINTING
Site address
8380 N. BOOTH
City
KANSAS CITY
State
MO
ZIP
64158
Mailing
5434 BURGEOIS ROAD, HOUSTON, TX 77066
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.95 A

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $500.00 Reduced
29 CFR 1926.95(a): "Application." Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.:     (a). Worksite located at 8380 N. Booth, Kansas City, Missouri- Employees were exposed to hazards from working with chemicals such as, but not limited to, vinyl sealer and were not provided personal protective equipment such as respirators, eye protection and protective gloves.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2400

1926.150 C01 VI

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not  provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite. This requirement does not apply to the integral fuel tanks of motor vehicles:     (a). Worksite located at 8380 N. Booth, Kansas City, Missouri- Employees were exposed to fire hazards while working with numerous gallons of vinyl sealer and stain,  both of which are highly flammable and being sprayed on the wood forming a mist without the use of any extinguishment equipment in proximity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $500.00 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer did not  use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:     (a). Worksite located at 8380 N.  Booth, Kanas City, Missouri- Employees were exposed to a shock or electrocution hazard in that the employees had plugged an extension cord in to an outlet that was not provided a groundfault circuit interrupter.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1600

1926.404 F05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $500.00 Reduced
29 CFR 1926.404(f)(5)(i): Grounded system. For a grounded system, a grounding electrode conductor  was not used to connect both the equipment grounding conductor and the grounded circuit conductor to the grounding electrode. Both the equipment grounding conductor and the grounding electrode conductor shall be connected to the grounded circuit conductor on the supply side of the service disconnecting means, or on the supply side of the system disconnecting means or overcurrent devices if the system is separately derived:     (a). Worksite located at 8380 N.  Booth, Kansas City, Missouri- Employees were exposed to a shock or electrocution hazard in that the employees had used a two-prong extension cord to power a tool, electric sprayer, which required a grounding receptacle. The employees then plugged the cord in to a non-GFCI protected outlet which also had reversed polarity.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2800

1926.405 A02 II J

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $500.00 Reduced
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances not three-wire type and were not designed for hard or extra-hard usage.    NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, some of which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords include hard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO).     (a). Worksite located at 8030 N. Booth, Kansas City, Missouri- Employees were exposed to a shock, fire or electrocution hazard in that the employees were observed using a two-prong, low-voltage rated extension cord that was plugged in to a non-GFCI protected outlet which also had reversed polarity.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339437865.