OSHA Inspection: SHELTON CONCRETE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SHELTON CONCRETE INC. in 285 GOLDEN HILL STREET, BRIDGEPORT, CT 06604 (NAICS 238110). OSHA activity number 339443160.

Watch Shelton Concrete INC. — free Get an email when a new federal OSHA severe-injury report for Shelton Concrete INC. is published. One employer, no account, unsubscribe in one click.
Site address
285 GOLDEN HILL STREET
City
BRIDGEPORT
State
CT
ZIP
06604
Mailing
12 APPLEWOOD DRIVE, SHELTON, CT 06484
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2200.00 · Current $2200.00
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.    WORKSITE: The employees, removing concrete forms from an excavation measuring approximately 141 feet long, between 10'-10"and 16'-6" wide, and between 5'-0" and 14'-6" deep were not provided with a safe means of egress at least every 25 feet throughout the excavation.
Recent events (3)
  • — F (S) $2200
  • — C (S) $2200
  • — Z (S) $2200

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2200.00 · Current $2200.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence.     WORKSITE: The employer did not conduct thorough inspection of the excavation for unsafe conditions, such as (but not limited to) safe means of egress and the need for cave-in protection.
Recent events (3)
  • — F (S) $2200
  • — C (S) $2200
  • — Z (S) $2200

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    WORKSITE: The employees, removing concrete forms from an excavation measuring approximately 141 feet long, between 10'-10" and 16'-6" wide, and between 5'-0" and 14'-6" deep were not provided with cave-in protection.
Recent events (3)
  • — F (S) $3080
  • — C (S) $3080
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1760.00 · Current $1760.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    WORKSITE: The Husky, 5-foot fibergalss stepladder, used by employees to egress the excavation did not extend at least 3-feet above the excavation, and no handhold or equivalent was provided.
Recent events (3)
  • — F (S) $1760
  • — C (S) $1760
  • — Z (S) $1760

1926.1053 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder shall not be used as a step.    WORKSITE: The Husky 5-foot fiberglass stepladder, used by employees to egress the excavation, was setup in the closed position and employees had to use the top step of the stepladder to egress the excavation.