Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENRIQUE ROQUE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENRIQUE ROQUE in 4920 ADRIAN CAMPOS ST., EL PASO, TX 79938 (NAICS 238130). OSHA activity number 339448383.

Watch Enrique Roque — free Get an email when a new federal OSHA severe-injury report for Enrique Roque is published. One employer, no account, unsubscribe in one click.
Establishment
ENRIQUE ROQUE
Site address
4920 ADRIAN CAMPOS ST.
City
EL PASO
State
TX
ZIP
79938
Mailing
5752 WEST VALLEY CIRCLE, EL PASO, TX 79932
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:     On or about October 29, 2013, in front and to the rear of the house, the top-plate and outer edges of the trusses; three employees were observed working on 5:12 pitched roof trusses without utilizing any fall protection system. The employees were exposed to a fall hazard of greater than six feet.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.405 G02 IV

Other-than-serious 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $200.00 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:     On or about October 29, 2013, inside the house under construction, electrical extension cords and an Electric Air Compressor had broken strain relief in the following instances:      a)    Rolair Systems, Wheeled Electric Air Compressor, electrical cable (male end).    b)    A 100-foot yellow extension cord (male end) used to power the DeWalt 7 ¼-inches Circular Saw.     c)     A 100-foot red extension cord (male end) used to power the Hitachi 7 ¼-inches Circular Saw.