OSHA Inspection: CAMAS CERAMIC TILES, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CAMAS CERAMIC TILES, LLC in 314 52ND STREET, BROOKLYN, NY 11220 (NAICS 238340). OSHA activity number 339450678.

Watch Camas Ceramic Tiles, LLC — free Get an email when a new federal OSHA severe-injury report for Camas Ceramic Tiles, LLC is published. One employer, no account, unsubscribe in one click.
Site address
314 52ND STREET
City
BROOKLYN
State
NY
ZIP
11220
Mailing
2311 ST. REYMOND AVENUE 3RD FLOOR, BRONX, NY 10462
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238340
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.404 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.404(b)(1): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    Location: 314 52nd Street Brooklyn, NY.    On or About: 10/30/13    a) The Huski work light being used by the employees was not provided with a GFCI protection or an assured equipment grounding program.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.    Location: 314 52nd Street Brookly, NY.  On or About: 10/30/13  a) The orange 25 feet extension cord use to energize the Husky working light was missing the ground pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.   Location: 314 52nd Street Brooklyn, NY  On or about: 10/30/13   a) Employees used a power trip to energize a Husky Work Light. The power trip was not listed and labeled to be used in construction.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339450678.