Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SOLO CUP CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOLO CUP CORPORATION in 1550 WRIGHTSBORO ROAD, AUGUSTA, GA 30904 (NAICS 326199). OSHA activity number 339454076.

Watch Solo CUP Corporation — free Get an email when a new federal OSHA severe-injury report for Solo CUP Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1550 WRIGHTSBORO ROAD
City
AUGUSTA
State
GA
ZIP
30904
Mailing
1550 WRIGHTSBORO ROAD, AUGUSTA, GA 30904
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
291
Ownership type
A

7 citations on file for this inspection.

1910.160 B06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4675.00 · Current $2800.00 Reduced
29 CFR 1910.160(b)(6): Fixed extinguishing systems were not inspected annually by a person knowledgeable in the design and function of the system to assure that the system is maintained in good operating condition:     On or about 10/30/13 at Augusta, GA:  Employees were exposed to fire related hazards while working on the Line One Thermoformer in the Dinnerware Department.  The employer failed to conduct an annual inspection on the the line's fixed CO2 fire extinguisher.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4675

1910.212 A01

Serious Gravity 10 17 instances 4 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5900.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts:    On or about 10/30/13 at Augusta, GA: Employees were exposed to unguarded rotating parts while operating Printer/Former machines and Leak Testers at the facility.      The employer failed to guard two openings on the operator's side of the Former machines.  The first opening is 42 inches wide by 12 inches in height.  The second opeinging is 100 inches long by 4 inches in height.  All of the following Former machines have the identical machine guarding issues:  a. Former #1  b. Former #2  c. Former #3  d. Former #4  e. Former #5  f.  Former #6  g. Former #7  h. Former #9  i.  Former #10  j.  Fomrer #11  k. Former #12  l.  Former #13  m.Former #14  n. Former #15  o. Former #16  p. Former #17  q. Former #18  r. Former #19    The employer failed to guard the following Leak Testers machines:  a. Leak Tester #2: The right side guard was missing.  b. Leak Tester #3: Guards on both sides of the tester were missing.
Recent events (2)
  • — I (S) $5900
  • — Z (S) $7000

1910.212 A03 II

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $3500.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     On or about 10/30/13 at Augusta, GA:  Employees were exposed to struck-by and caught between hazards while operating two milling machines in the Maintenance Shop.  The employer failed to properly guard the following two milling machines' point of operation.     a. Bridgeport Milling Machine   b. Supermax Milling Machine.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.219 C04 I

Serious Gravity 5 32 instances 5 exposed
Issued
Abate by
Penalty
Initial $4675.00 · Current $2800.00 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:    On or about 10/30/13 at Augusta, GA: Employees were exposed to caught between hazards while performing work in the Printer/Former Area.  The employer failed to ensure that projected shaft ends were at a length less that one half the diameter of the shaft in the following instances:    a. Printer #1: The Lof & Sons Printer had 4 shafts that were 5 inches in length and 1 1/4 inches in diameter.  b. Printer #2: The Lof & Sons Printer had 4 shafts that were 5.5 inches in length and 1 1/4 inches in diameter.  c. Printer #9: The Lof & Sons Printer had 8 shafts that  were 7 inches in length and 1 1/4 inches in diameter.  d. Printer  #10: The Lof & Sons Printer had 4 shafts that were 4.5 inches in length and 1 1/4 inches in diameter.  e. Printer  #11: The Lof & Sons Printer had 4 shafts that were 4.5 inches in length and 1 1/4 inches in diameter.  f.  Printer #14:  The Lof & Sons Printer had 8 shafts that were 4.5 inches in length and 1 1/4 inches in diameter.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4675

1910.303 F02

Serious Gravity 1 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2805.00 · Current $1700.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On or about 10/30/13 at Augusta, GA: Employees were exposed to electrical hazards while working in the Mold Shop and Dinnerware Department.  Circuit brieakers located in two electrical panels were not marked as to their purpose / location:    a. Dinnerware Department:  Circuit breakers in electrical panel 2J-4 were not marked as to their purpose.    b. Mold Shop:  Circuit breakers in electrical panel PNLLV-2 were not marked as to their purpose.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2805

1910.303 G02 I

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $4675.00 · Current $2800.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about 10/30/13 at Augusta, GA: Employees were exposed to electrical hazards when accessing electrical panels in the Dinnerware Department and the Mold Shop.  The employer failed to effectively guard all unclosed openings within the electrical panels to prevent accidental contact by employees.    a. Dinnerware Department:  Electrical Panel 1AA-3 had 4 unclosed openings on the panel.  b. Mold Department:  Electrical Panel PNLLV-2 had 3 unclosed openings on the panel.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4675

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   On or about 10/30/13 at Augusta, GA: Employees were exposed to electrical hazards while working on the P1 repel Line, located in the Dinnerware Department.  The employer failed to provide adequate strain relief on an electrical cable located at the bottom of the P1 repel Drive Cabinet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339454076.