COLUMBUS, OH —
OSHA Inspection: KCL FRAMING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KCL FRAMING in 1231 GABRIELLE ELAINE DR., COLUMBUS, OH 43228 (NAICS 238130). OSHA activity number 339454357.
Where did this inspection happen?
- Establishment
- KCL FRAMING
- Site address
- 1231 GABRIELLE ELAINE DR.
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 7849 PATTERSON ROAD, HILLIARD, OH 43026
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 A04
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $640.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. a. On Building 5 where employees were using a Sky Trak rough terrain forklift to lift trusses into place without written permission from the manufactuer when modifing the use of the powered industrial truck thereby exposing employees to a struck-by hazard.
Recent events (2)
- — I (S) $640
- — Z (S) $1600
1926.405 A02 II I
- Issued
- Penalty
- Initial $1200.00 · Current $480.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage. a. At the front of Building 10, there was a extension cord which ran across the dirt road and was exposed to damage from vehicle traffic to provide power to the framers on the roof thereby exposing employees to a contact hazard.
Recent events (2)
- — I (S) $480
- — Z (S) $1200
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1920.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. a. On the roof of building 5 where the employees were framing the roof deck, KCL Framing did not ensure the employes of Alderete Construction were wearing fall protection thereby exposing employees to a fall hazard.
Recent events (2)
- — I (S) $1920
- — Z (S) $2800
1926.602 C01 VIII A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(viii)(A): Use of a safety platform firmly secured to the lifting carriage and/or forks. a. On the site beside building 5, the platform on the front of the rough terrain forklift was not secured to the forks to prevent displacement when lifting trusses thereby exposing employees to a struck-by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.1052 C01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $480.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with: 29 CFR 1926.1052(c)(1)(i): At least one handrail; a. In Building 5 where employees used the stairways to gain access to the second floor and then onto the roof to perform framing, there were no handrails thereby exposing employees to a trip/fall hazard.
Recent events (2)
- — I (S) $480
- — Z (S) $1200
More inspections at KCL FRAMING
REYNOLDSBURG, OH—2000-06-27 00:00:00
KCL FRAMING
View KCL FRAMING's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339454357.