Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DELTA PLATING, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DELTA PLATING, INC. in 2125 HARRISON AVE, CANTON, OH 44706 (NAICS 332813). OSHA activity number 339458473.

Watch Delta Plating, INC. — free Get an email when a new federal OSHA severe-injury report for Delta Plating, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DELTA PLATING, INC.
Site address
2125 HARRISON AVE
City
CANTON
State
OH
ZIP
44706
Mailing
2125 HARRISON AVE, CANTON, OH 44706
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
24
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 24 exposed
Issued
Penalty
Initial $2040.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards:  On or about November 4, 2013, employees were exposed to a struck by hazard when lifting loads with devices that were not rated or marked. The company was not performing frequent inspections (daily to monthly intervals) of the company's overhead hoists, located in the plating area. Three hoists were noted as not having pendants marked with the operational direction.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2040

1910.124 G02

Serious Gravity 5 1 instance 24 exposed
Issued
Penalty
Initial $2040.00 · Current $1020.00 Reduced
29 CFR 1910.124(g)(2): Employees who worked with liquids that could burn, irritate, or otherwise harm their skin were not provided with an emergency shower and eye-wash station close to the dipping and coating operation:    On or about November 04, 2013, the Plating Department did not have access to an emergency shower and eye-wash station for employees who work with liquids that could burn, irritate, or harm their skin.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $2040

1910.147 C04 II

Other-than-serious 3 instances 24 exposed
Issued
Penalty
Initial $1700.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii):  The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section:    On or about November 4, 2013, lockout/tagout procedures did not clearly and specifically identify the following aspects necessary to control hazardous energy on equipment such as, but not limited to; the polishing machine #18 and #20:    a.  The steps for removing the lockout or tagout device.   b.  Steps for inspecting the machine and their componenets to assure that they are operationally intact before being placed back into service.  c.   Steps to assure that everyone is positioned safely away from machines before powering back up.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1700

1910.147 C06 I

Serious Gravity 5 1 instance 24 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:                                                                                                              On or about November 4, 2013, periodic inspections were not conducted of lockout/tagout procedures necessary to control the hazardous energy of machines such as, but not limited to, polishing machine #18 and #20.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.305 B01 II

Serious Gravity 5 1 instance 24 exposed
Issued
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:      On or about November 4, 2013, the electrical panel located on the north wall near the plating line was open and had unused openings in the box exposing employees to live electrical when accessing the breakers.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.1026 L01

Serious Gravity 5 3 instances 24 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced

Hazardous substances C111

29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication standard, 29 CFR 1910.1200:    On or about November 22, 2013, a hoist operator working with chromic acid in the plating department was exposed to chromium (VI) fumes at 2.3 ug/m3 which is approximately 0.46 times the permissible exposure limit of 5 ug/m3; exposure calculations included a zero increment for the 111 minutes not sampled. The employer did not ensure that all employees who are exposed to chromium (VI) were provided with information and training.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.1200 F06 I

Serious Gravity 1 1 instance 24 exposed
Issued
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v):    On or about November 4, 2013, the employer did not ensure that containers were labeled with the identity of the chemical. Unlabeled containers were located in the plating and dipping departments.
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

1910.132 D02

Other-than-serious 1 instance 24 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:   On or about November 4, 2013, the workplace hazard assessment had not been certified with the person conducting the evaluation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339458473.