OSHA Inspection: JOSE SANTO CANALES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE SANTO CANALES in 5807 CITY PARK RD., AUSTIN, TX 78730 (NAICS 238130). OSHA activity number 339463887.

Watch Jose Santo Canales — free Get an email when a new federal OSHA severe-injury report for Jose Santo Canales is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE SANTO CANALES
Site address
5807 CITY PARK RD.
City
AUSTIN
State
TX
ZIP
78730
Mailing
1004 GARDEN PATH, ROUND ROCK, TX 78664
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.  On or about 24 October 2013, three employees were performing framing activities at a residential home under construction. Employees were standing and working beneath each other while using a pneumatic nail gun and passing pieces of lumber up to one another without the use of head protection, exposing the employees to the hazard of being struck by falling objects.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.416 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used.  On or about 24 October 2013, employees were utilizing a 120-V, yellow extension cord with damage to the outer sheathing that exposed the insulated wires, exposing the employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1926.451 G01 VII

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On or about 24 October 2013,  two employees were required to work from a temporary scaffold set up approximately 15 feet high in the front entrance of the home under construction without fall protection, exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.451 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide.  On or about 24 October 2013, two employees were working from a temporary scaffold up to approximately 15 feet high without the platform being at least 18 inches wide, exposing the employee to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).  On or about 24 October 2013, an employee was conducting house framing work and installing joists on the top of the 2nd floor of the home under construction up to approximately 21 feet high without fall protection, exposing the employee to a fall hazard.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards.  On or about 24 October 2013, four employees were conducting house framing work and installing joists on the top of the 2nd floor of the home under construction up to approximately 21 feet high without the employer providing fall protection training, exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B13

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step.  On or about 24 October 2013, two employees utilized the top step of a 3-foot, portable, free standing ladder to access the temporary scaffolding built approximately 5 feet high around the residential home under construction, exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339463887.