BIG SPRING, TX —
OSHA Inspection: WEST TEXAS ENERGY SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WEST TEXAS ENERGY SERVICES in 4 MILES EAST OF BIG SPRING, TX., BIG SPRING, TX 79720 (NAICS 213111). OSHA activity number 339480303.
Where did this inspection happen?
- Establishment
- WEST TEXAS ENERGY SERVICES
- Site address
- 4 MILES EAST OF BIG SPRING, TX.
- City
- BIG SPRING
- State
- TX
- ZIP
- 79720
- Mailing
- P.O. BOX 1888, BIG SPRING, TX 79720
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 69
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 E01
- Issued
- Abate by
- Penalty
- Initial $2618.00 · Current $1571.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: On or about November 06, 2013, and at times prior thereto, employees were working on a rig site, Rig # 2. The railing between the suction pit #1 and shale pit #2 was missing the intermediate rail on both sides of the crossover. The employees were exposed to potential falls of more than 4 feet to the ground below.
Recent events (2)
- — I (S) $1570.8
- — Z (S) $2618
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $2618.00 · Current $1571.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about November 06, 2013, and at times prior thereto, employees were working on a rig site, Rig #2. There were two units on the site which were not grounded properly: 1. The bottom doghouse had a rod buried only six inches in the ground and 2. The toolpusher trailer was not grounded at all. Employees were exposed to potential electric shock and/or burns.
Recent events (2)
- — I (S) $1570.8
- — Z (S) $2618
1910.305 J01 I
- Issued
- Abate by
- Penalty
- Initial $2618.00 · Current $1571.00 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: On or about November 06, 2013, and at times prior thereto, employees were working on a rig site, Rig #2. The Parts House light had a missing cover and exposed live wires. This condition exposed employees to potential electric hazards.
Recent events (2)
- — I (S) $1570.8
- — Z (S) $2618
1910.22 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(b)(1): 29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard: On or about November 06, 2013 and at times, prior thereto, employees were working at a rig site, Rig # 2. The floor going from the rig floor to the doghouse was bent up, rising up approximately 2.5 inches at some points. This created a trip hazard for employees.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: On or about November 06, 2013, and at times prior thereto, employees were working on a rig site, Rig #2. In the bottom doghouse, the heater cord was run through a hole in the metal wall. This condition exposed employees to potential electric hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables used were run through doorways, windows, or similar openings: On or about November 06, 2013, and at times prior thereto, employees were working on a rig site, Rig #2. At the site, there were two occasions where electric cords were run through metal doors. One was running from the chemical pump to the main fuse box/transformer. The other was at the bottom doghouse where the cord to the interior light was run to the outside through the metal door. The employees were exposed to potential electric hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at WEST TEXAS ENERGY SERVICES
IRA, TX—1999-04-20 00:00:00
WEST TEXAS ENERGY SERVICES
View WEST TEXAS ENERGY SERVICES's full OSHA safety record →
More inspections in this industry (NAICS 213111)
JAL, NM—2026-07-01
HELMERICH & PAYNE, IDC
LAREDO, TX—2026-06-28
AXIS ENERGY SERVICES
MCALESTER, OK—2026-06-18
SANGUINE GAS EXPLORATION, LLC
MOUNT PLEASANT, MI—2026-06-15
BIGARD & HUGGARD DRILLING INC
MOUNT PLEASANT, MI—2026-06-15
BIGARD & HUGGARD DRILLING INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339480303.