OCALA, FL —
OSHA Inspection: TRIDENT ROOFING OF FLORIDA, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRIDENT ROOFING OF FLORIDA, INC. in 901 E SILVER SPRINGS BLVD., OCALA, FL 34471 (NAICS 238160). OSHA activity number 339481137.
Where did this inspection happen?
- Establishment
- TRIDENT ROOFING OF FLORIDA, INC.
- Site address
- 901 E SILVER SPRINGS BLVD.
- City
- OCALA
- State
- FL
- ZIP
- 34471
- Mailing
- 6328 SE CEDAR ROAD, BELLEVIEW, FL 34420
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about November 5,2013, two employees using nail guns were not wearing safety glasses, exposing themselves to eye injuries. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.501 B10
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system: a. On or about November 5, 2013, two employees installing shingles on a 4:12 pitch roof were not protected from falling 9.5 feet by the use of a guardrail system, safety net system, or personal fall arrest system. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder�s length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about November 5, 2013, side of the building, the 14-foot extension ladder used by the employees to access and exit from the roof was not secured to prevent accidental displacement, exposing the employees to a 9.5 feet fall hazard. Abatement Certification and Documentation are not required
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339481137.