Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JR MCGEE PLUMBING, LLC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of JR MCGEE PLUMBING, LLC. in 800 N DELEWARE AVE, PHILADELPHIA, PA 19123 (NAICS 238220). OSHA activity number 339484248.

Watch JR Mcgee Plumbing, LLC. — free Get an email when a new federal OSHA severe-injury report for JR Mcgee Plumbing, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
800 N DELEWARE AVE
City
PHILADELPHIA
State
PA
ZIP
19123
Mailing
6 DEER PARK CIRCLE, BLACKWOOD, NJ 08012
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.651 J02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1250.00 Reduced
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection by placing and keeping such materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary was not provided.    a) Jobsite: First floor, south end - On or about 10/29/13, JR McGee exposed his employees to falling object hazards by not keeping excavated material with loose rock at least 2 feet away from the edge of the excavation.  Employees were installing cast iron sewer pipes.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2000

1926.652 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).    a) Jobsite: First floor, south end - On or about 10/29/13, a protective system was not used to protect employees from cave-in hazards while installing a cast iron sewer pipe inside the excavation measuring approximately 5 feet 10 inches in depth, 10 feet 8 inches in length, and  3 feet 1 inch in width.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.651 K01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1250.00 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person prior to the start of work, and as needed throughout the shift, for evidence of situations that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.    a) Jobsite: First floor, south end - On or about 10/29/13, JR McGee Plumbing did not conduct daily inspections of the excavation and adjacent areas for evidence of situations that could result in cave-ins, or other hazardous conditions.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $2000

1926.21 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    a) Jobsite: First floor, south end - On or about 10/29/13, JR McGee did not instruct each employee in the recognition and avoidance of unsafe conditions at the jobsite to control or eliminate protective system failures during excavation operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B04

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed.  a) Jobsite: First floor, south end - On or about 10/29/13, employees installing cast iron sewer pipes in an excavation were exposed to hazards associated with excavation operations while working with a ladder that was not used for the purpose for which it was designed.  The Husky 8 foot fiberglass supported (A-Frame) step ladder used in the excavation to access the upper working level was not used as designed by the manufacturer exposing employees to fall hazards.  The ladder was used in a folded position, not opened according to the manufacturer's specifications.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339484248.