SOUTH HEMPSTEAD, NY —
OSHA Inspection: JOSE NELSON CHEVEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOSE NELSON CHEVEZ in 1129 LONG BEACH RD., SOUTH HEMPSTEAD, NY 11550 (NAICS 238140). OSHA activity number 339484826.
Where did this inspection happen?
- Establishment
- JOSE NELSON CHEVEZ
- Site address
- 1129 LONG BEACH RD.
- City
- SOUTH HEMPSTEAD
- State
- NY
- ZIP
- 11550
- Mailing
- 1042 WOOL AVE., FRANKLIN SQUARE, NY 11010
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: a) Worksite, 1129 Long Beach Rd. South Hempstead NY - Employees were installing styrofoam to a two story commercial building while working from a fabricated frame scaffold that was not fully planked. The scaffold had two planks installed at the working level, approximately 12ft above the ground; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Worksite, 1129 Long Beach Rd. South Hempstead NY - Employees were installing styrofoam to a two story commercial building while working from a fabricated frame scaffold. The employees were climbing the crossbraces to gain access to the scaffold; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
1926.451 F06
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) Worksite, 1129 Long Beach Rd. South Hempstead NY - Employees were installing styrofoam on a two story commercial building while working on a fabricated frame scaffold. The employees were working less than 2ft away from an energized secondary line; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, 1129 Long Beach Rd. South Hempstead NY - Employees were exposed to falling while working from the platform of a fabricated frame scaffold approximately 12ft above the ground; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source